#  ACIQ AEP80 Exhaust Fan Specifications

ENERGY STAR PD #3629725 · Bathroom/Utility Room · Qualified 2024-09-27

Verified Specification Summary

The ACIQ AEP80 (AEP) moves 80 CFM at 0.1 in. w.g. (70.9 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones), and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 70 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEP80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 70.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 88.6% @ 0.25"

- **Motor Draw**: 19.0 W (6.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does ACIQ AEP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.9 CFM out of 80 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places AEP80 (series: AEP) (PD #3629725) among 15 ACIQ entries qualified through 2024-09-27. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.0 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 166.4 kWh/yr (~$26.62/yr) continuously. Closest competing matches include Canarm CEP80 (80.0 CFM) and Cyclone ESCBP80 (80.0 CFM).

## Where does ACIQ AEP80 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.7 sones against all 1,145 EPA listings.

## How does duct geometry alter ACIQ AEP80 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to ACIQ AEP80?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for ACIQ AEP80 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | ACIQ (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AEP80 / AEP | PD ID 3629725 (Qualified 2024-09-27) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (70.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can ACIQ AEP80 ventilate safely?

Sizing outputs below convert ACIQ AEP80 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for ACIQ AEP80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 19.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 166.4 kWh/yr (~$26.62/yr) | 19.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match ACIQ AEP80 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Canarm CEP80**](https://siematic-charleston.com/ventilation-fans/canarm-cep80/) | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**Cyclone ESCBP80**](https://siematic-charleston.com/ventilation-fans/cyclone-escbp80/) | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**Revent RVPR80**](https://siematic-charleston.com/ventilation-fans/revent-rvpr80/) | 80 / 66.2 CFM | 0.7 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Ortech ODE-8007**](https://siematic-charleston.com/ventilation-fans/ortech-ode-8007/) | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Air King AK80LS**](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls/) | 80 / 61.5 CFM | 0.7 sones (Same) | 4.5 CFM/W | 4 in. diameter |

## Will ACIQ AEP80 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether ACIQ AEP80 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip ACIQ AEP80 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for ACIQ AEP80 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 20 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 70 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern ACIQ AEP80?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting ACIQ AEP80.

### Will long attic ducting choke ACIQ AEP80 capacity?

Because static drag at 0.25 in. w.g. lowers ACIQ AEP80 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is ACIQ AEP80 compared with a standard 3.0 sone builder fan?

Tested at 0.7 sones, ACIQ AEP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does ACIQ AEP80 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, ACIQ AEP80 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can ACIQ AEP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing ACIQ AEP80?

ACIQ AEP80 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change ACIQ AEP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEP80's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does ACIQ AEP80 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), ACIQ AEP80 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify ACIQ AEP80?

Rule out ACIQ AEP80 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## Which guides and calculators connect next to ACIQ AEP80?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for ACIQ AEP80.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [ACIQ AES80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aes80/)
- [Air King AK80LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls/)
- [S&P PC80XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pc80xp-3626825/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)