title: "ACIQ AEPD140-3 Bath Fan (140 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aciq-aepd140-3/
description: "ENERGY STAR specs for ACIQ AEPD140-3: 140 CFM, 11.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  ACIQ AEPD140-3 Exhaust Fan Specifications

ENERGY STAR PD #3984073 · Bathroom/Utility Room · Qualified 2025-01-24

Verified Specification Summary

In EPA dataset 8dv7-nngq, ACIQ AEPD140-3 tests at 140 CFM free discharge (146.6 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 146 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEPD140-3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 140 / 146.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.5 CFM/W (#106/1,145)

- **Static Retention**: 104.7% @ 0.25"

- **Motor Draw**: 12.2 W (4.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does ACIQ AEPD140-3 vs. 1,145-Model ENERGY STAR Benchmarks show?

ACIQ AEPD140-3 (EPA filing PD #3984073) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #3984073 verifies AEPD140-3 (series: AEPD) under ACIQ (15 listed models, qualified 2025-01-24). Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and CFM TF140-EC (140.0 CFM).

## Why avoid unvented attic termination with ACIQ AEPD140-3?

Under ASHRAE 62.2 best practice, ACIQ AEPD140-3 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern ACIQ AEPD140-3?

Before cutting ceiling drywall or sizing attic transitions for ACIQ AEPD140-3, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | ACIQ (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AEPD140-3 / AEPD | PD ID 3984073 (Qualified 2025-01-24) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (146.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit ACIQ AEPD140-3?

Bathroom ventilation sizing below maps ACIQ AEPD140-3 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for ACIQ AEPD140-3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 146 sq ft | 1 CFM/sq ft @ 146.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 130 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 96 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest ACIQ AEPD140-3 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to ACIQ AEPD140-3.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**CFM TF140-EC**](https://siematic-charleston.com/ventilation-fans/cfm-tf140-ec/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**Haier QVE110DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve110dtww/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**Ortech ODD-110-18PB**](https://siematic-charleston.com/ventilation-fans/ortech-odd-110-18pb/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**S&P PCD110XP**](https://siematic-charleston.com/ventilation-fans/s-p-pcd110xp/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |

## What percentage of room demand does ACIQ AEPD140-3 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against ACIQ AEPD140-3 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install ACIQ AEPD140-3 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting ACIQ AEPD140-3 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 146.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 146 sq ft
- **Primary match:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for ACIQ AEPD140-3?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing ACIQ AEPD140-3.

### Does ACIQ AEPD140-3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), ACIQ AEPD140-3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is ACIQ AEPD140-3 undersized or poorly matched for a bath renovation?

Skip ACIQ AEPD140-3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check ACIQ AEPD140-3 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, ACIQ AEPD140-3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does ACIQ AEPD140-3 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, ACIQ AEPD140-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define ACIQ AEPD140-3?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can ACIQ AEPD140-3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEPD140-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing ACIQ AEPD140-3?

ACIQ AEPD140-3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change ACIQ AEPD140-3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEPD140-3's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on ACIQ AEPD140-3?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan L100E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l100e/)
- [CFM TF140-EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cfm-tf140-ec/)
- [Elica EAL330ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/elica-eal330es/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)