title: "ACIQ AESD100-3 Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aciq-aesd100-3/
description: "ENERGY STAR specs for ACIQ AESD100-3: 100 CFM, 9.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  ACIQ AESD100-3 Exhaust Fan Specifications

ENERGY STAR PD #3998904 · Bathroom/Utility Room · Qualified 2025-01-24

Verified Specification Summary

Certified by EPA ENERGY STAR, ACIQ AESD100-3 delivers 100 CFM free-air (106.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 106 sq ft (8-ft height) or 94 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AESD100-3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.3 CFM/W (#258/1,145)

- **Static Retention**: 106.5% @ 0.25"

- **Motor Draw**: 10.8 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does ACIQ AESD100-3 vs. 1,145-Model ENERGY STAR Benchmarks show?

ACIQ AESD100-3 (EPA filing PD #3998904) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: ACIQ registers 15 certified models, with SKU AESD100-3 (series: AESD) (PD #3998904) certified since 2025-01-24. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect ACIQ AESD100-3 airflow?

Connecting ACIQ AESD100-3 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify ACIQ AESD100-3 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for ACIQ AESD100-3 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | ACIQ (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AESD100-3 / AESD | PD ID 3998904 (Qualified 2025-01-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit ACIQ AESD100-3?

Calculated coverage metrics translate ACIQ AESD100-3 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for ACIQ AESD100-3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to ACIQ AESD100-3?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does ACIQ AESD100-3 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check ACIQ AESD100-3 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying ACIQ AESD100-3?

Match ACIQ AESD100-3 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 106.5 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for ACIQ AESD100-3?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around ACIQ AESD100-3.

### What does ACIQ AESD100-3 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running ACIQ AESD100-3 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can ACIQ AESD100-3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AESD100-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing ACIQ AESD100-3?

ACIQ AESD100-3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change ACIQ AESD100-3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AESD100-3's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can ACIQ AESD100-3 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), ACIQ AESD100-3 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does ACIQ AESD100-3 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with ACIQ AESD100-3.

### What happens to ACIQ AESD100-3 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, ACIQ AESD100-3 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does ACIQ AESD100-3 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, ACIQ AESD100-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## Where can you explore more benchmarks around ACIQ AESD100-3?

Use the related reference pages and estimators below to cross-check ACIQ AESD100-3 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King AK100D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak100d/)
- [Air King ESQZ2303 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esqz2303/)
- [Win Air BPT14-24A-2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24a-2/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)