Verified Specification Summary

The AERO PURE ABF110DHL6W (ABF) moves 110 CFM at 0.1 in. w.g. (93.9 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 7.4 CFM/W efficacy, sizing bathrooms up to 93 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF110DHL6W Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 93.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.4 CFM/W (#392/1,145)

- **Static Retention**: 85.4% @ 0.25"

- **Motor Draw**: 14.9 W (5.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AERO PURE ABF110DHL6W vs. 1,145-Model ENERGY STAR Benchmarks show?

AERO PURE ABF110DHL6W (EPA filing PD #2338639) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.9 CFM out of 110 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms AERO PURE ABF110DHL6W (series: ABF) under PD #2338639 (14 models registered, 2019-05-17). Lighting kit: Yes. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.9 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 130.5 kWh/yr (~$20.88/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Delta 100LED (100.0 CFM).

## How does duct geometry alter AERO PURE ABF110DHL6W static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to AERO PURE ABF110DHL6W?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for AERO PURE ABF110DHL6W alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ABF110DHL6W / ABF | PD ID 2338639 (Qualified 2019-05-17) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (93.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can AERO PURE ABF110DHL6W ventilate safely?

Sizing outputs below convert AERO PURE ABF110DHL6W tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF110DHL6W

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.4 kWh/yr (~$0.86/yr) | 14.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 130.5 kWh/yr (~$20.88/yr) | 14.9 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match AERO PURE ABF110DHL6W closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Delta 100LED**](https://siematic-charleston.com/ventilation-fans/delta-100led/) | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| [**Delta GBR100LED**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led/) | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| [**Delta ITG100**](https://siematic-charleston.com/ventilation-fans/delta-itg100/) | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| [**Utilitech 7131-04**](https://siematic-charleston.com/ventilation-fans/utilitech-7131-04/) | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |

## Will AERO PURE ABF110DHL6W clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether AERO PURE ABF110DHL6W satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out AERO PURE ABF110DHL6W?

Compare where AERO PURE ABF110DHL6W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 93 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern AERO PURE ABF110DHL6W?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting AERO PURE ABF110DHL6W.

### How does AERO PURE ABF110DHL6W handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AERO PURE ABF110DHL6W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is AERO PURE ABF110DHL6W quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, AERO PURE ABF110DHL6W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is AERO PURE ABF110DHL6W energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can AERO PURE ABF110DHL6W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF110DHL6W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AERO PURE ABF110DHL6W?

AERO PURE ABF110DHL6W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AERO PURE ABF110DHL6W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF110DHL6W's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can AERO PURE ABF110DHL6W serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AERO PURE ABF110DHL6W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap AERO PURE ABF110DHL6W for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AERO PURE ABF110DHL6W lacks adequate reserve.

## Which guides and calculators connect next to AERO PURE ABF110DHL6W?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for AERO PURE ABF110DHL6W.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AERO PURE ABFS0511DL6W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abfs0511dl6w/)
- [Air King E80S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-e80s/)
- [AERO PURE ABF110DHL5W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110dhl5w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)