#  AERO PURE ABF110G16W Exhaust Fan Specifications

ENERGY STAR PD #2331230 · Bathroom/Utility Room · Qualified 2018-12-07

Verified Specification Summary

Rated for 110 CFM open-air (83.6 CFM at 0.25 in. w.g.), AERO PURE ABF110G16W registers #357 of 607 in quietness (1.1 sones) and delivers 4.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 83 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF110G16W Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 83.6 CFM

- **Noise @ 0.1"**: 1.1 sones (#357/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 76.0% @ 0.25"

- **Motor Draw**: 25.0 W (9.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AERO PURE ABF110G16W vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 83.6 CFM at 0.25 in. w.g. (76.0% retention, 11.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ABF110G16W (series: ABF) (PD #2331230) among 14 AERO PURE entries qualified through 2018-12-07. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include AUPU AV11A3 (110.0 CFM) and Miseno MBF110AWH (110.0 CFM).

## How does AERO PURE ABF110G16W acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against AERO PURE ABF110G16W (1.1 sones).

## How do flex elbows choke AERO PURE ABF110G16W at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps AERO PURE ABF110G16W moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does AERO PURE ABF110G16W meet residential exhaust fan code specs?

Inspect AERO PURE ABF110G16W mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ABF110G16W / ABF | PD ID 2331230 (Qualified 2018-12-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (83.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match AERO PURE ABF110G16W airflow output?

Annual electricity figures and room square-footage ceilings below reflect AERO PURE ABF110G16W tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF110G16W

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 83 sq ft | 1 CFM/sq ft @ 83.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 33 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |

## Which competing models share AERO PURE ABF110G16W airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**AUPU AV11A3**](https://siematic-charleston.com/ventilation-fans/aupu-av11a3/) | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Miseno MBF110AWH**](https://siematic-charleston.com/ventilation-fans/miseno-mbf110awh/) | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Aria QBV01100**](https://siematic-charleston.com/ventilation-fans/aria-qbv01100/) | 110 / 101.5 CFM | 1.1 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Good Housekeeping 84006**](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84006/) | 110 / 101.5 CFM | 1.1 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Air King AK110LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak110ls6/) | 110 / 103.3 CFM | 1.1 sones (Same) | 3.9 CFM/W | 6 in. diameter |

## How much airflow margin does AERO PURE ABF110G16W give your bath?

Run a quick local room-volume check for AERO PURE ABF110G16W by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install AERO PURE ABF110G16W in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AERO PURE ABF110G16W for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 33 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 83 sq ft with 8-ft ceilings (74 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about AERO PURE ABF110G16W?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to AERO PURE ABF110G16W.

### Does AERO PURE ABF110G16W satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF110G16W clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is AERO PURE ABF110G16W undersized or poorly matched for a bath renovation?

Skip AERO PURE ABF110G16W if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check AERO PURE ABF110G16W CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AERO PURE ABF110G16W registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does AERO PURE ABF110G16W sound output compare to noisy contractor-grade fans?

Rated at 1.1 sones, AERO PURE ABF110G16W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define AERO PURE ABF110G16W?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can AERO PURE ABF110G16W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF110G16W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AERO PURE ABF110G16W?

AERO PURE ABF110G16W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AERO PURE ABF110G16W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF110G16W's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with AERO PURE ABF110G16W?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to AERO PURE ABF110G16W.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King AK110LS6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak110ls6/)
- [Aria QBV01100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aria-qbv01100/)
- [Ortech ODC-1109 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odc-1109/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)