---
title: "AERO PURE ABF80L5OR Bath Fan (80 CFM, 0.6 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/
description: "ENERGY STAR specs for AERO PURE ABF80L5OR: 80 CFM, 0.6 sones (#107 of 607), 4.4 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  AERO PURE ABF80L5OR Exhaust Fan Specifications

ENERGY STAR PD #4498422 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

In EPA dataset 8dv7-nngq, AERO PURE ABF80L5OR tests at 80 CFM free discharge (61.4 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 61 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF80L5OR Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 61.4 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 76.8% @ 0.25"

- **Motor Draw**: 18.2 W (6.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AERO PURE ABF80L5OR vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.4 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: AERO PURE registers 14 certified models, with SKU ABF80L5OR (series: ABF80L5OR) (PD #4498422) certified since 2025-06-06. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Dayton 1UBH7B (80.0 CFM) and Greenheck SP-B80 (80.0 CFM).

## Does AERO PURE ABF80L5OR fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AERO PURE ABF80L5OR at 0.6 sones.

## Why avoid unvented attic termination with AERO PURE ABF80L5OR?

Under ASHRAE 62.2 best practice, AERO PURE ABF80L5OR needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern AERO PURE ABF80L5OR?

Before cutting ceiling drywall or sizing attic transitions for AERO PURE ABF80L5OR, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ABF80L5OR / ABF80L5OR | PD ID 4498422 (Qualified 2025-06-06) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (61.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit AERO PURE ABF80L5OR?

Bathroom ventilation sizing below maps AERO PURE ABF80L5OR motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF80L5OR

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest AERO PURE ABF80L5OR in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AERO PURE ABF80L5OR.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 1UBH7B**](https://siematic-charleston.com/ventilation-fans/dayton-1ubh7b/) | 80 / N/A CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| [**Greenheck SP-B80**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b80/) | 80 / 62 CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-04-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-plus/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**VENTECHLATION VF-BF-03**](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-03/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**VENTECHLATION VF-BF-11L**](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-11l/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |

## What percentage of room demand does AERO PURE ABF80L5OR cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AERO PURE ABF80L5OR tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying AERO PURE ABF80L5OR?

Match AERO PURE ABF80L5OR directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 61.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 0.6 sones up to 61 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for AERO PURE ABF80L5OR?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AERO PURE ABF80L5OR.

### Where does AERO PURE ABF80L5OR sit on acoustic comfort for senior homeowners?

Measuring 0.6 sones, AERO PURE ABF80L5OR operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does AERO PURE ABF80L5OR cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running AERO PURE ABF80L5OR 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can AERO PURE ABF80L5OR pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF80L5OR's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AERO PURE ABF80L5OR?

AERO PURE ABF80L5OR features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AERO PURE ABF80L5OR's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF80L5OR's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can AERO PURE ABF80L5OR ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF80L5OR covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does AERO PURE ABF80L5OR run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with AERO PURE ABF80L5OR.

### What happens to AERO PURE ABF80L5OR CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, AERO PURE ABF80L5OR moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## What related resources expand on AERO PURE ABF80L5OR?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AERO PURE ABF80L5SG Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sg/)
- [AERO PURE ABF80L5SN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sn/)
- [ACIQ ANP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-anp80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
