title: "AERO PURE ABF80L5SG Bath Fan (80 CFM, 0.6 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sg/
description: "ENERGY STAR specs for AERO PURE ABF80L5SG: 80 CFM, 0.6 sones (#107 of 607), 4.4 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  AERO PURE ABF80L5SG Exhaust Fan Specifications

ENERGY STAR PD #4498423 · Bathroom/Utility Room · Qualified 2025-06-06

Verified Specification Summary

Tested under HVI protocols, the AERO PURE ABF80L5SG exhaust unit achieves 80 CFM at 0.1 in. w.g. (61.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones) and delivers 4.4 CFM/W efficacy, covering standard baths up to 61 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF80L5SG Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 61.4 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 76.8% @ 0.25"

- **Motor Draw**: 18.2 W (6.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AERO PURE ABF80L5SG vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.4 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside AERO PURE's 14-unit lineup, ABF80L5SG (series: ABF80L5SG) carries PD #4498423 dating to 2025-06-06. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Dayton 1UBH7B (80.0 CFM) and Greenheck SP-B80 (80.0 CFM).

## Where do AERO PURE ABF80L5SG sones rank across EPA ENERGY STAR fans?

Comparing AERO PURE ABF80L5SG (0.6 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves AERO PURE ABF80L5SG CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AERO PURE ABF80L5SG, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does AERO PURE ABF80L5SG measure up on airflow and noise ratings?

Each row below breaks down AERO PURE ABF80L5SG certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ABF80L5SG / ABF80L5SG | PD ID 4498423 (Qualified 2025-06-06) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (61.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect AERO PURE ABF80L5SG CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF80L5SG

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against AERO PURE ABF80L5SG?

Compare AERO PURE ABF80L5SG side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 1UBH7B**](https://siematic-charleston.com/ventilation-fans/dayton-1ubh7b/) | 80 / N/A CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| [**Greenheck SP-B80**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b80/) | 80 / 62 CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-04-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-plus/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**VENTECHLATION VF-BF-03**](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-03/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**VENTECHLATION VF-BF-11L**](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-11l/) | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |

## Can you size AERO PURE ABF80L5SG for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AERO PURE ABF80L5SG verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip AERO PURE ABF80L5SG on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for AERO PURE ABF80L5SG carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 61.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 0.6 sones up to 61 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to AERO PURE ABF80L5SG?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AERO PURE ABF80L5SG.

### Will long attic ducting choke AERO PURE ABF80L5SG capacity?

Because static drag at 0.25 in. w.g. lowers AERO PURE ABF80L5SG from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is AERO PURE ABF80L5SG compared with a standard 3.0 sone builder fan?

Tested at 0.6 sones, AERO PURE ABF80L5SG operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does AERO PURE ABF80L5SG consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, AERO PURE ABF80L5SG draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can AERO PURE ABF80L5SG pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF80L5SG's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AERO PURE ABF80L5SG?

AERO PURE ABF80L5SG features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AERO PURE ABF80L5SG's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF80L5SG's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does AERO PURE ABF80L5SG score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF80L5SG delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify AERO PURE ABF80L5SG?

Rule out AERO PURE ABF80L5SG when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What neighboring pages and tools support AERO PURE ABF80L5SG?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around AERO PURE ABF80L5SG.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AERO PURE ABF80L5SN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sn/)
- [AERO PURE ABF80L5W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5w/)
- [AERO PURE ABF80L5OR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)