---
title: "AERO PURE ABFS0511DL6W Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aero-pure-abfs0511dl6w/
description: "ENERGY STAR specs for AERO PURE ABFS0511DL6W: 110 CFM, 7.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  AERO PURE ABFS0511DL6W Exhaust Fan Specifications

ENERGY STAR PD #4587266 · Bathroom/Utility Room · Qualified 2026-04-08

Verified Specification Summary

Certified by EPA ENERGY STAR, AERO PURE ABFS0511DL6W delivers 110 CFM free-air (111.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 111 sq ft (8-ft height) or 98 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABFS0511DL6W Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 111.2 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.8 CFM/W (#365/1,145)

- **Static Retention**: 101.1% @ 0.25"

- **Motor Draw**: 14.1 W (5.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AERO PURE ABFS0511DL6W vs. 1,145-Model ENERGY STAR Benchmarks show?

AERO PURE ABFS0511DL6W (EPA filing PD #4587266) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.2 CFM out of 110 CFM (101.1% retention, 13.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms AERO PURE ABFS0511DL6W (series: ABFS0511) under PD #4587266 (14 models registered, 2026-04-08). Lighting kit: No. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.1 watts, about 5.1 kWh/yr (~$0.82/yr at $0.16/kWh) for 1 hr/day shower timers or 123.5 kWh/yr (~$19.76/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect AERO PURE ABFS0511DL6W airflow?

Connecting AERO PURE ABFS0511DL6W through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify AERO PURE ABFS0511DL6W performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AERO PURE ABFS0511DL6W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ABFS0511DL6W / ABFS0511 | PD ID 4587266 (Qualified 2026-04-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (111.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit AERO PURE ABFS0511DL6W?

Calculated coverage metrics translate AERO PURE ABFS0511DL6W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AERO PURE ABFS0511DL6W

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.1 kWh/yr (~$0.82/yr) | 14.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 123.5 kWh/yr (~$19.76/yr) | 14.1 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to AERO PURE ABFS0511DL6W?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does AERO PURE ABFS0511DL6W match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AERO PURE ABFS0511DL6W percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out AERO PURE ABFS0511DL6W?

Compare where AERO PURE ABFS0511DL6W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 61 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 111.2 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for AERO PURE ABFS0511DL6W?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AERO PURE ABFS0511DL6W.

### Is AERO PURE ABFS0511DL6W energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can AERO PURE ABFS0511DL6W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABFS0511DL6W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AERO PURE ABFS0511DL6W?

AERO PURE ABFS0511DL6W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AERO PURE ABFS0511DL6W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABFS0511DL6W's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can AERO PURE ABFS0511DL6W serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AERO PURE ABFS0511DL6W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap AERO PURE ABFS0511DL6W for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AERO PURE ABFS0511DL6W lacks adequate reserve.

### How does AERO PURE ABFS0511DL6W handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AERO PURE ABFS0511DL6W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is AERO PURE ABFS0511DL6W quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, AERO PURE ABFS0511DL6W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Where can you explore more benchmarks around AERO PURE ABFS0511DL6W?

Use the related reference pages and estimators below to cross-check AERO PURE ABFS0511DL6W against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King E80S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-e80s/)
- [Air King E80SH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-e80sh/)
- [AERO PURE ABF110DHL6W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110dhl6w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
