title: "Air King AK80H Bath Fan (80 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-ak80h/
description: "ENERGY STAR specs for Air King AK80H: 80 CFM, 1.0 sones (#265 of 607), 3.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Air King AK80H Exhaust Fan Specifications

ENERGY STAR PD #2395011 · Bathroom/Utility Room · Qualified 2022-04-22

Verified Specification Summary

Tested under HVI protocols, the Air King AK80H exhaust unit achieves 80 CFM at 0.1 in. w.g. (71.4 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 3.8 CFM/W efficacy, covering standard baths up to 71 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK80H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 71.4 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 89.2% @ 0.25"

- **Motor Draw**: 21.1 W (7.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King AK80H vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.4 CFM out of 80 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Air King registers 62 certified models, with SKU AK80H (series: Air King) (PD #2395011) certified since 2022-04-22. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.1 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 184.8 kWh/yr (~$29.57/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-80-CTA (80.0 CFM) and HomeWerks Worldwide 7141-80-HW (80.0 CFM).

## Where do Air King AK80H sones rank across EPA ENERGY STAR fans?

Comparing Air King AK80H (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Air King AK80H CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Air King AK80H, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Air King AK80H measure up on airflow and noise ratings?

Each row below breaks down Air King AK80H certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK80H / Air King | PD ID 2395011 (Qualified 2022-04-22) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Air King AK80H CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Air King AK80H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.7 kWh/yr (~$1.23/yr) | 21.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 184.8 kWh/yr (~$29.57/yr) | 21.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Air King AK80H?

Compare Air King AK80H side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7141-80-CTA**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-cta/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-hw/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-RGB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-rgb/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Utilitech 7141-80-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7141-80-l/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |

## Can you size Air King AK80H for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Air King AK80H verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Air King AK80H?

Compare where Air King AK80H excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 71.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 1.0 sones up to 71 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Air King AK80H?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Air King AK80H.

### Can Air King AK80H serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King AK80H supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Air King AK80H for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King AK80H lacks adequate reserve.

### How does Air King AK80H handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King AK80H yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Air King AK80H quiet enough for a primary bedroom bathroom?

At 1.0 sones, Air King AK80H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Air King AK80H energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Air King AK80H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK80H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King AK80H?

Air King AK80H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King AK80H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK80H's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Air King AK80H?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Air King AK80H.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King AK80LS1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/)
- [Air King FR80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-fr80/)
- [ACIQ AP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-ap80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)