title: "Air King AK80LS1 Bath Fan (80 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/
description: "ENERGY STAR specs for Air King AK80LS1: 80 CFM, 1.0 sones (#265 of 607), 3.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Air King AK80LS1 Exhaust Fan Specifications

ENERGY STAR PD #2395010 · Bathroom/Utility Room · Qualified 2022-04-22

Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King AK80LS1 tests at 80 CFM free discharge (71.4 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 71 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK80LS1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 71.4 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 89.2% @ 0.25"

- **Motor Draw**: 21.1 W (7.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King AK80LS1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.4 CFM out of 80 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; AK80LS1 (series: Air King) (PD #2395010) gained qualification on 2022-04-22. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.1 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 184.8 kWh/yr (~$29.57/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-80-CTA (80.0 CFM) and HomeWerks Worldwide 7141-80-HW (80.0 CFM).

## Does Air King AK80LS1 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King AK80LS1 at 1.0 sones.

## Why avoid unvented attic termination with Air King AK80LS1?

Under ASHRAE 62.2 best practice, Air King AK80LS1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Air King AK80LS1?

Before cutting ceiling drywall or sizing attic transitions for Air King AK80LS1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK80LS1 / Air King | PD ID 2395010 (Qualified 2022-04-22) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Air King AK80LS1?

Bathroom ventilation sizing below maps Air King AK80LS1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King AK80LS1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.7 kWh/yr (~$1.23/yr) | 21.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 184.8 kWh/yr (~$29.57/yr) | 21.1 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Air King AK80LS1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King AK80LS1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7141-80-CTA**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-cta/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-hw/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-RGB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-rgb/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Utilitech 7141-80-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7141-80-l/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |

## What percentage of room demand does Air King AK80LS1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King AK80LS1 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Air King AK80LS1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King AK80LS1 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 71.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.0 sones up to 71 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Air King AK80LS1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King AK80LS1.

### How much power does Air King AK80LS1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Air King AK80LS1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Air King AK80LS1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK80LS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King AK80LS1?

Air King AK80LS1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King AK80LS1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK80LS1's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Air King AK80LS1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King AK80LS1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Air King AK80LS1?

Rule out Air King AK80LS1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Air King AK80LS1 capacity?

Because static drag at 0.25 in. w.g. lowers Air King AK80LS1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Air King AK80LS1 compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Air King AK80LS1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

## What related resources expand on Air King AK80LS1?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King FR80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-fr80/)
- [Air King FR80H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-fr80h/)
- [Air King AK80H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80h/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)