title: "Air King BFC90 Bath Fan (90 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-bfc90/
description: "ENERGY STAR specs for Air King BFC90: 90 CFM, 1.0 sones (#265 of 607), 4.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Air King BFC90 Exhaust Fan Specifications

ENERGY STAR PD #2287992 · Bathroom/Utility Room · Qualified 2017-01-06

Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King BFC90 tests at 90 CFM free discharge (75.6 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 75 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFC90 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 75.6 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 4.7 CFM/W (#545/1,145)

- **Static Retention**: 84.0% @ 0.25"

- **Motor Draw**: 19.1 W (7.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King BFC90 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 75.6 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Air King's 62-unit lineup, BFC90 (series: Air King) carries PD #2287992 dating to 2017-01-06. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 19.1 watts, about 7.0 kWh/yr (~$1.12/yr at $0.16/kWh) for 1 hr/day shower timers or 167.3 kWh/yr (~$26.77/yr) continuously. Closest competing matches include Good Housekeeping 84005 (100.0 CFM) and Broan AE100B = A000HFKT with AE100BF1 (100.0 CFM).

## Does Air King BFC90 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King BFC90 at 1.0 sones.

## Why avoid unvented attic termination with Air King BFC90?

Under ASHRAE 62.2 best practice, Air King BFC90 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Air King BFC90?

Before cutting ceiling drywall or sizing attic transitions for Air King BFC90, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BFC90 / Air King | PD ID 2287992 (Qualified 2017-01-06) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (75.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Air King BFC90?

Bathroom ventilation sizing below maps Air King BFC90 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King BFC90

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 67 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.0 kWh/yr (~$1.12/yr) | 19.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 167.3 kWh/yr (~$26.77/yr) | 19.1 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Air King BFC90 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King BFC90.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Good Housekeeping 84005**](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84005/) | 100 / 92.3 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Broan AE100B = A000HFKT with AE100BF1**](https://siematic-charleston.com/ventilation-fans/broan-ae100b-a000hfkt-with-ae100bf1/) | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Broan AE100B = A000HFNF with AE100BF1**](https://siematic-charleston.com/ventilation-fans/broan-ae100b-a000hfnf-with-ae100bf1/) | 100 / 95.5 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Panasonic FV-08VRE2**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-08vre2/) | 80 / 66.7 CFM | 1.0 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7117-01-BN**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7117-01-bn/) | 80 / 65.4 CFM | 1.1 sones (+0.10) | 4.6 CFM/W | 4 in. diameter |

## What percentage of room demand does Air King BFC90 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King BFC90 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Air King BFC90?

Compare where Air King BFC90 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 75.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 1.0 sones up to 75 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Air King BFC90?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King BFC90.

### How does Air King BFC90 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King BFC90 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Air King BFC90 quiet enough for a primary bedroom bathroom?

At 1.0 sones, Air King BFC90 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Air King BFC90 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Air King BFC90 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFC90's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King BFC90?

Air King BFC90 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King BFC90's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFC90's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Air King BFC90 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King BFC90 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Air King BFC90 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King BFC90 lacks adequate reserve.

## What related resources expand on Air King BFC90?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King BFC90H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfc90h/)
- [ACIQ AP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-ap80/)
- [Good Housekeeping 84005 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84005/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)