title: "Air King E80SH Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-e80sh/
description: "ENERGY STAR specs for Air King E80SH: 110 CFM, 4.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Air King E80SH Exhaust Fan Specifications

ENERGY STAR PD #2254291 · Bathroom/Utility Room · Qualified 2015-12-01

Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King E80SH tests at 110 CFM free discharge (115.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 115 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King E80SH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 115.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 105.4% @ 0.25"

- **Motor Draw**: 24.4 W (8.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King E80SH vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King E80SH (EPA filing PD #2254291) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 115.9 CFM out of 110 CFM (105.4% retention, 17.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Air King's 62-unit lineup, E80SH (series: N/A) carries PD #2254291 dating to 2015-12-01. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Tech Drive FA-BF-04-L(BL) (110.0 CFM) and Tech Drive FA-BF-04-L(BN) (110.0 CFM).

## Why avoid unvented attic termination with Air King E80SH?

Under ASHRAE 62.2 best practice, Air King E80SH needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Air King E80SH?

Before cutting ceiling drywall or sizing attic transitions for Air King E80SH, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | E80SH / N/A | PD ID 2254291 (Qualified 2015-12-01) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (115.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Air King E80SH?

Bathroom ventilation sizing below maps Air King E80SH motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King E80SH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 115 sq ft | 1 CFM/sq ft @ 115.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 103 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 65 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Air King E80SH in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King E80SH.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive FA-BF-04-L(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-bl/) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(BN)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-bn/) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(WH)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-wh/) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
| [**Broan 791LEDM**](https://siematic-charleston.com/ventilation-fans/broan-791ledm/) | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| [**Commercial Electric BPT14-24OD-H**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt14-24od-h/) | 110 / 98.1 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |

## What percentage of room demand does Air King E80SH cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King E80SH tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Air King E80SH in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King E80SH for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 115.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 115 sq ft
- **Primary match:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Air King E80SH?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King E80SH.

### Does Air King E80SH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King E80SH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Air King E80SH undersized or poorly matched for a bath renovation?

Skip Air King E80SH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Air King E80SH CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King E80SH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Air King E80SH sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Air King E80SH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Air King E80SH?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Air King E80SH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King E80SH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King E80SH?

Air King E80SH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King E80SH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King E80SH's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on Air King E80SH?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AUPU AV0511DSL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-av0511dsl3/)
- [AUPU AVS0511DL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-avs0511dl3/)
- [Air King E80S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-e80s/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)