#  Air King ESZ306ADA Exhaust Fan Specifications

ENERGY STAR PD #2369806 · Range Hood · Qualified 2020-11-20

Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King ESZ306ADA tests at 120 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 120 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESZ306ADA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 120 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.9 CFM/W (#356/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 15.2 W (5.5 kWh/yr)

- **Duct & Tier**: 3.25 x 1 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King ESZ306ADA vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King ESZ306ADA (EPA filing PD #2369806) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.

EPA filing PD #2369806 verifies ESZ306ADA (series: Air King) under Air King (62 listed models, qualified 2020-11-20). Lighting kit: Yes. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## Why avoid unvented attic termination with Air King ESZ306ADA?

Under ASHRAE 62.2 best practice, Air King ESZ306ADA needs insulated 3.25 x 1 in. rectangular rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Air King ESZ306ADA?

Before cutting ceiling drywall or sizing attic transitions for Air King ESZ306ADA, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ESZ306ADA / Air King | PD ID 2369806 (Qualified 2020-11-20) |
| **Duct Connection** | 3.25 x 1 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Air King ESZ306ADA?

Bathroom ventilation sizing below maps Air King ESZ306ADA motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King ESZ306ADA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 133.2 kWh/yr (~$21.31/yr) | 15.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Air King ESZ306ADA in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King ESZ306ADA.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## What percentage of room demand does Air King ESZ306ADA cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King ESZ306ADA tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Air King ESZ306ADA suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King ESZ306ADA for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 120 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around ENERGY STAR sones up to 120 sq ft
- **Best application:** Paired with rigid galvanized 3.25 x 1 in. rectangular transition

## Where do official rules set limits for Air King ESZ306ADA?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King ESZ306ADA.

### How many kWh per year does Air King ESZ306ADA add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Air King ESZ306ADA averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Air King ESZ306ADA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESZ306ADA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King ESZ306ADA?

Air King ESZ306ADA features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King ESZ306ADA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESZ306ADA's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Air King ESZ306ADA pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King ESZ306ADA easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Air King ESZ306ADA in a bathroom remodel?

Avoid specifying Air King ESZ306ADA in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Air King ESZ306ADA airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King ESZ306ADA achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3.25 x 1 in. rectangular smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Air King ESZ306ADA occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Air King ESZ306ADA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## What related resources expand on Air King ESZ306ADA?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King ESZ363ADA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esz363ada/)
- [Air King ESZ368ADA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esz368ada/)
- [Air King ESZ303ADA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esz303ada/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)