#  Air King FR80 Exhaust Fan Specifications

ENERGY STAR PD #4480286 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Tested under HVI protocols, the Air King FR80 exhaust unit achieves 80 CFM at 0.1 in. w.g. (71.4 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 3.8 CFM/W efficacy, covering standard baths up to 71 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King FR80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 71.4 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 89.2% @ 0.25"

- **Motor Draw**: 21.1 W (7.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King FR80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.4 CFM out of 80 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Air King FR80 (series: Air King) under PD #4480286 (62 models registered, 2025-07-25). Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.1 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 184.8 kWh/yr (~$29.57/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-80-CTA (80.0 CFM) and HomeWerks Worldwide 7141-80-HW (80.0 CFM).

## Where do Air King FR80 sones rank across EPA ENERGY STAR fans?

Comparing Air King FR80 (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Air King FR80 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Air King FR80, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Air King FR80 measure up on airflow and noise ratings?

Each row below breaks down Air King FR80 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FR80 / Air King | PD ID 4480286 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Air King FR80 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Air King FR80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.7 kWh/yr (~$1.23/yr) | 21.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 184.8 kWh/yr (~$29.57/yr) | 21.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Air King FR80?

Compare Air King FR80 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7141-80-CTA**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-cta/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-hw/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-80-RGB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-rgb/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Utilitech 7141-80-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7141-80-l/) | 80 / 59 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |

## Can you size Air King FR80 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Air King FR80 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Air King FR80 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King FR80.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 71.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 1.0 sones up to 71 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Air King FR80?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Air King FR80.

### Will Air King FR80 disturb adjacent bedrooms during night use?

Acoustic measurement places Air King FR80 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Air King FR80 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Air King FR80 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Air King FR80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King FR80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King FR80?

Air King FR80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King FR80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King FR80's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Air King FR80 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King FR80 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Air King FR80?

Do not force Air King FR80 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Air King FR80 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Air King FR80 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## What neighboring pages and tools support Air King FR80?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Air King FR80.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King FR80H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-fr80h/)
- [Broan EZ80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/)
- [Air King AK80LS1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)