title: "Air King FR90 Bath Fan (90 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-fr90/
description: "ENERGY STAR specs for Air King FR90: 90 CFM, 1.5 sones (#412 of 607), 3.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Air King FR90 Exhaust Fan Specifications

ENERGY STAR PD #4480284 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Homeowners specifying Air King FR90 gain 90 CFM at 0.1 in. w.g. (73.2 CFM at 0.25 in. w.g.) where it registers #412 of 607 in quietness (1.5 sones) and delivers 3.7 CFM/W efficacy, venting bathrooms up to 73 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King FR90 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 73.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 81.3% @ 0.25"

- **Motor Draw**: 24.3 W (8.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King FR90 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 73.2 CFM at 0.25 in. w.g. (81.3% retention, 6.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Air King FR90 (series: Air King) under PD #4480284 (62 models registered, 2025-07-25). Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.3 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 212.9 kWh/yr (~$34.06/yr) continuously. Closest competing matches include Home Netwerks 7105-09-BN (90.0 CFM) and HomeWerks Worldwide 7105-09-MB (90.0 CFM).

## What acoustic percentile does Air King FR90 occupy among 1,145 bath blowers?

Inspect how Air King FR90 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Air King FR90 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Air King FR90 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Air King FR90 acoustic and static metrics stand?

Compare Air King FR90 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FR90 / Air King | PD ID 4480284 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (73.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Air King FR90 handle taller ceilings or walk-in tub steam?

Evaluate how Air King FR90 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Air King FR90

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 73 sq ft | 1 CFM/sq ft @ 73.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 65 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 23 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.9 kWh/yr (~$34.06/yr) | 24.3 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Air King FR90?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Home Netwerks 7105-09-BN**](https://siematic-charleston.com/ventilation-fans/home-netwerks-7105-09-bn/) | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7105-09-MB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-09-mb/) | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| [**Utilitech 7105-09-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7105-09-l/) | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-11**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11/) | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Akicon AK1390N1-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n1-w-b-s/) | 90 / 67.4 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |

## Is Air King FR90 sized right for your shower or tub room?

Check whether Air King FR90 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Air King FR90?

Compare where Air King FR90 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 23 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 73.2 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Air King FR90?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Air King FR90.

### Why might a contractor swap Air King FR90 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King FR90 lacks adequate reserve.

### How does Air King FR90 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King FR90 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Air King FR90 quiet enough for a primary bedroom bathroom?

At 1.5 sones, Air King FR90 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Air King FR90 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Air King FR90 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King FR90's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King FR90?

Air King FR90 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King FR90's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King FR90's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Air King FR90 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King FR90 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## How can you cross-check Air King FR90 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Air King FR90.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Akicon AK1390N1-W/B/S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n1-w-b-s/)
- [Akicon AK1390N2-B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/)
- [Utilitech 7131-04 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7131-04/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)