#  Air King WM50 Exhaust Fan Specifications

ENERGY STAR PD #2389099 · Bathroom/Utility Room · Qualified 2021-12-10

Verified Specification Summary

The Air King WM50 (Air King) moves 50 CFM at 0.1 in. w.g. (37.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones), and delivers 2.9 CFM/W efficacy, sizing bathrooms up to 37 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King WM50 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 37.4 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 2.9 CFM/W (#1,132/1,145)

- **Static Retention**: 74.8% @ 0.25"

- **Motor Draw**: 17.2 W (6.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King WM50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 37.4 CFM at 0.25 in. w.g. (74.8% retention, 12.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Air King WM50 (series: Air King) under PD #2389099 (62 models registered, 2021-12-10). Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-50-G4 (50.0 CFM) and HomeWerks Worldwide 7141-50 (50.0 CFM).

## Where does Air King WM50 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.6 sones against all 1,145 EPA listings.

## How does duct geometry alter Air King WM50 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Air King WM50?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King WM50 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | WM50 / Air King | PD ID 2389099 (Qualified 2021-12-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (37.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Air King WM50 ventilate safely?

Sizing outputs below convert Air King WM50 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Air King WM50

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 37 sq ft | 1 CFM/sq ft @ 37.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 33 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Air King WM50 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7141-50-G4**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50-g4/) | 50 / 35.9 CFM | 0.7 sones (+0.10) | 2.9 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-50**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50/) | 50 / 36.3 CFM | 0.7 sones (+0.10) | 3.0 CFM/W | 4 in. diameter |
| [**Broan-Nutone BENL5**](https://siematic-charleston.com/ventilation-fans/broan-nutone-benl5/) | 50 / 49.5 CFM | 0.7 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| [**Broan AE50**](https://siematic-charleston.com/ventilation-fans/broan-ae50/) | 50 / 51.9 CFM | 0.5 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Broan AE50=A000HF2WITHAE50F**](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hf2withae50f/) | 50 / 51.9 CFM | 0.5 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |

## Will Air King WM50 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Air King WM50 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Air King WM50 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King WM50 for your remodel.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 37 sq ft with 8-ft ceilings (33 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Air King WM50?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King WM50.

### Who should NOT install Air King WM50 in a bathroom remodel?

Avoid specifying Air King WM50 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Air King WM50 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King WM50 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Air King WM50 occupy in EPA filings?

With 0.6 sones at 0.1 in. w.g., Air King WM50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Air King WM50 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Air King WM50 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Air King WM50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King WM50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King WM50?

Air King WM50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King WM50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King WM50's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Air King WM50 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King WM50 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## Which guides and calculators connect next to Air King WM50?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Air King WM50.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVS150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvs150/)
- [Revent RVSH150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh150/)
- [Air King FR50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-fr50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)