title: "Air King WM70 Bath Fan (70 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/air-king-wm70/
description: "ENERGY STAR specs for Air King WM70: 70 CFM, 2.0 sones (#522 of 607), 3.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Air King WM70 Exhaust Fan Specifications

ENERGY STAR PD #2389098 · Bathroom/Utility Room · Qualified 2021-12-10

Verified Specification Summary

The Air King WM70 (Air King) moves 70 CFM at 0.1 in. w.g. (60.6 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 3.4 CFM/W efficacy, sizing bathrooms up to 60 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King WM70 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60.6 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.4 CFM/W (#1,060/1,145)

- **Static Retention**: 86.6% @ 0.25"

- **Motor Draw**: 20.6 W (7.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Air King WM70 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.6 CFM out of 70 CFM (86.6% retention, 1.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Air King's 62-unit lineup, WM70 (series: Air King) carries PD #2389098 dating to 2021-12-10. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Hampton Bay BF70HD (70.0 CFM) and HomeWerks Worldwide 7140-70-HW (70.0 CFM).

## Where does Air King WM70 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Air King WM70 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Air King WM70?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King WM70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Air King (62 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | WM70 / Air King | PD ID 2389098 (Qualified 2021-12-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Air King WM70 ventilate safely?

Sizing outputs below convert Air King WM70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Air King WM70

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Air King WM70 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hampton Bay BF70HD**](https://siematic-charleston.com/ventilation-fans/hampton-bay-bf70hd/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7140-70-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-70-hw/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**PROJECT SOURCE 7140-70-PS**](https://siematic-charleston.com/ventilation-fans/project-source-7140-70-ps/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**PROJECT SOURCE 8771-70-PS**](https://siematic-charleston.com/ventilation-fans/project-source-8771-70-ps/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**PROJECT SOURCE 8772-70-PS**](https://siematic-charleston.com/ventilation-fans/project-source-8772-70-ps/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |

## Will Air King WM70 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Air King WM70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Air King WM70 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King WM70.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Air King WM70?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King WM70.

### Will Air King WM70 disturb adjacent bedrooms during night use?

Acoustic measurement places Air King WM70 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Air King WM70 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Air King WM70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Air King WM70 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King WM70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Air King WM70?

Air King WM70 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Air King WM70's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King WM70's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Air King WM70 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King WM70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Air King WM70?

Do not force Air King WM70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Air King WM70 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Air King WM70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Which guides and calculators connect next to Air King WM70?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Air King WM70.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King WML70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-wml70/)
- [Broan BEL7A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-bel7a/)
- [Air King BFQL70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfql70/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)