title: "Akicon AK1390N2-S Bath Fan (90 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-s/
description: "ENERGY STAR specs for Akicon AK1390N2-S: 90 CFM, 1.5 sones (#412 of 607), 4.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Akicon AK1390N2-S Exhaust Fan Specifications

ENERGY STAR PD #4008353 · Bathroom/Utility Room · Qualified 2025-03-28

Verified Specification Summary

Tested under HVI protocols, the Akicon AK1390N2-S exhaust unit achieves 90 CFM at 0.1 in. w.g. (71.7 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 71 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N2-S Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 71.7 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 79.7% @ 0.25"

- **Motor Draw**: 21.4 W (7.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Akicon AK1390N2-S vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.7 CFM at 0.25 in. w.g. (79.7% retention, 8.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Akicon's 14-unit lineup, AK1390N2-S (series: AK1390N2-S) carries PD #4008353 dating to 2025-03-28. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech ODE-9010 (90.0 CFM) and Panasonic Eco Solutions RG-V80A (90.0 CFM).

## Where do Akicon AK1390N2-S sones rank across EPA ENERGY STAR fans?

Comparing Akicon AK1390N2-S (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Akicon AK1390N2-S CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Akicon AK1390N2-S, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Akicon AK1390N2-S measure up on airflow and noise ratings?

Each row below breaks down Akicon AK1390N2-S certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Akicon (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK1390N2-S / AK1390N2-S | PD ID 4008353 (Qualified 2025-03-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Akicon AK1390N2-S CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Akicon AK1390N2-S

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Akicon AK1390N2-S?

Compare Akicon AK1390N2-S side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech ODE-9010**](https://siematic-charleston.com/ventilation-fans/ortech-ode-9010/) | 90 / 81.3 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Panasonic Eco Solutions RG-V80A**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-v80a/) | 90 / 79.2 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-11**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11/) | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Air King FR90**](https://siematic-charleston.com/ventilation-fans/air-king-fr90/) | 90 / 73.2 CFM | 1.5 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Home Netwerks 7105-09-BN**](https://siematic-charleston.com/ventilation-fans/home-netwerks-7105-09-bn/) | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |

## Can you size Akicon AK1390N2-S for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Akicon AK1390N2-S verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Akicon AK1390N2-S fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Akicon AK1390N2-S.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 71.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 1.5 sones up to 71 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Akicon AK1390N2-S?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Akicon AK1390N2-S.

### Will Akicon AK1390N2-S disturb adjacent bedrooms during night use?

Acoustic measurement places Akicon AK1390N2-S at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Akicon AK1390N2-S continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Akicon AK1390N2-S draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Akicon AK1390N2-S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N2-S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Akicon AK1390N2-S?

Akicon AK1390N2-S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Akicon AK1390N2-S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N2-S's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Akicon AK1390N2-S code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Akicon AK1390N2-S clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Akicon AK1390N2-S?

Do not force Akicon AK1390N2-S into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Akicon AK1390N2-S retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Akicon AK1390N2-S produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## What neighboring pages and tools support Akicon AK1390N2-S?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Akicon AK1390N2-S.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Akicon AK1390N2-W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-w/)
- [Akicon AK1390N3-W/B/S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n3-w-b-s/)
- [Akicon AK1390N2-B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)