title: "Akicon AK15110N5-B Bath Fan (110 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-b/
description: "ENERGY STAR specs for Akicon AK15110N5-B: 110 CFM, 1.5 sones (#412 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Akicon AK15110N5-B Exhaust Fan Specifications

ENERGY STAR PD #4592474 · Bathroom/Utility Room · Qualified 2026-03-25

Verified Specification Summary

Tested under HVI protocols, the Akicon AK15110N5-B exhaust unit achieves 110 CFM at 0.1 in. w.g. (100.5 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 100 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK15110N5-B Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 100.5 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 91.4% @ 0.25"

- **Motor Draw**: 28.2 W (10.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Akicon AK15110N5-B vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.5 CFM out of 110 CFM (91.4% retention, 3.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Akicon's 14-unit lineup, AK15110N5-B (series: AK15110N5-B) carries PD #4592474 dating to 2026-03-25. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Commercial Electric 7130-20-CE (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).

## Where do Akicon AK15110N5-B sones rank across EPA ENERGY STAR fans?

Comparing Akicon AK15110N5-B (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Akicon AK15110N5-B CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Akicon AK15110N5-B, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Akicon AK15110N5-B measure up on airflow and noise ratings?

Each row below breaks down Akicon AK15110N5-B certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Akicon (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK15110N5-B / AK15110N5-B | PD ID 4592474 (Qualified 2026-03-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Akicon AK15110N5-B CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Akicon AK15110N5-B

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Akicon AK15110N5-B?

Compare Akicon AK15110N5-B side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Commercial Electric 7130-20-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-20-ce/) | 110 / 98.4 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Commercial Electric 7130-16-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-16-ce/) | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBL**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgbl/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBLC**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgblc/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan AER110RGBL**](https://siematic-charleston.com/ventilation-fans/broan-aer110rgbl/) | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |

## Can you size Akicon AK15110N5-B for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Akicon AK15110N5-B verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Akicon AK15110N5-B on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Akicon AK15110N5-B carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 100.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.5 sones up to 100 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Akicon AK15110N5-B?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Akicon AK15110N5-B.

### What duct and room conditions disqualify Akicon AK15110N5-B?

Rule out Akicon AK15110N5-B when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Akicon AK15110N5-B capacity?

Because static drag at 0.25 in. w.g. lowers Akicon AK15110N5-B from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Akicon AK15110N5-B compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Akicon AK15110N5-B produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Akicon AK15110N5-B consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Akicon AK15110N5-B draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Akicon AK15110N5-B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK15110N5-B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Akicon AK15110N5-B?

Akicon AK15110N5-B features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Akicon AK15110N5-B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK15110N5-B's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Akicon AK15110N5-B score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Akicon AK15110N5-B delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## What neighboring pages and tools support Akicon AK15110N5-B?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Akicon AK15110N5-B.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Akicon AK15110N5-S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-s/)
- [Akicon AK15110N5-W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-w/)
- [Greenheck SP-B110ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)