title: "Akicon AK15110N5-W Bath Fan (110 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-w/
description: "ENERGY STAR specs for Akicon AK15110N5-W: 110 CFM, 1.5 sones (#412 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Akicon AK15110N5-W Exhaust Fan Specifications

ENERGY STAR PD #4592514 · Bathroom/Utility Room · Qualified 2026-03-25

Verified Specification Summary

Rated for 110 CFM open-air (100.5 CFM at 0.25 in. w.g.), Akicon AK15110N5-W registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK15110N5-W Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 100.5 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 91.4% @ 0.25"

- **Motor Draw**: 28.2 W (10.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Akicon AK15110N5-W vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.5 CFM out of 110 CFM (91.4% retention, 3.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Akicon AK15110N5-W (series: AK15110N5-W) under PD #4592514 (14 models registered, 2026-03-25). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Commercial Electric 7130-20-CE (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).

## How does Akicon AK15110N5-W acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Akicon AK15110N5-W (1.5 sones).

## How do flex elbows choke Akicon AK15110N5-W at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Akicon AK15110N5-W moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Akicon AK15110N5-W meet residential exhaust fan code specs?

Inspect Akicon AK15110N5-W mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Akicon (14 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK15110N5-W / AK15110N5-W | PD ID 4592514 (Qualified 2026-03-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Akicon AK15110N5-W airflow output?

Annual electricity figures and room square-footage ceilings below reflect Akicon AK15110N5-W tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Akicon AK15110N5-W

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |

## Which competing models share Akicon AK15110N5-W airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Commercial Electric 7130-20-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-20-ce/) | 110 / 98.4 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Commercial Electric 7130-16-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-16-ce/) | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBL**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgbl/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBLC**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgblc/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan AER110RGBL**](https://siematic-charleston.com/ventilation-fans/broan-aer110rgbl/) | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |

## How much airflow margin does Akicon AK15110N5-W give your bath?

Run a quick local room-volume check for Akicon AK15110N5-W by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Akicon AK15110N5-W fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Akicon AK15110N5-W.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 100 sq ft with 8-ft ceilings (89 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Akicon AK15110N5-W?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Akicon AK15110N5-W.

### Does running Akicon AK15110N5-W continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Akicon AK15110N5-W draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Akicon AK15110N5-W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK15110N5-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Akicon AK15110N5-W?

Akicon AK15110N5-W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Akicon AK15110N5-W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK15110N5-W's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Akicon AK15110N5-W code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Akicon AK15110N5-W clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Akicon AK15110N5-W?

Do not force Akicon AK15110N5-W into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Akicon AK15110N5-W retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Akicon AK15110N5-W produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Akicon AK15110N5-W disturb adjacent bedrooms during night use?

Acoustic measurement places Akicon AK15110N5-W at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## Which GradeMark tools pair best with Akicon AK15110N5-W?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Akicon AK15110N5-W.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan 791LEDM Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-791ledm/)
- [Broan AER110LTMB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-aer110ltmb/)
- [Akicon AK15110N5-S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-s/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)