#  Anzzi EF-AZ101WH Exhaust Fan Specifications

ENERGY STAR PD #3417978 · Bathroom/Utility Room · Qualified 2024-03-15

Verified Specification Summary

Rated for 80 CFM open-air (68.9 CFM at 0.25 in. w.g.), Anzzi EF-AZ101WH registers #135 of 607 in quietness (0.7 sones) and delivers 5.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 68 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ101WH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 5.3 CFM/W (#494/1,145)

- **Static Retention**: 86.1% @ 0.25"

- **Motor Draw**: 15.1 W (5.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Anzzi EF-AZ101WH vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.9 CFM out of 80 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Anzzi registers 8 certified models, with SKU EF-AZ101WH (series: EF) (PD #3417978) certified since 2024-03-15. Lighting kit: Yes. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.1 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 132.3 kWh/yr (~$21.17/yr) continuously. Closest competing matches include Aria QBV0800 (80.0 CFM) and Haier QVE801DTWW (80.0 CFM).

## How does Anzzi EF-AZ101WH acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Anzzi EF-AZ101WH (0.7 sones).

## How do flex elbows choke Anzzi EF-AZ101WH at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Anzzi EF-AZ101WH moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Anzzi EF-AZ101WH meet residential exhaust fan code specs?

Inspect Anzzi EF-AZ101WH mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Anzzi (8 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | EF-AZ101WH / EF | PD ID 3417978 (Qualified 2024-03-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Anzzi EF-AZ101WH airflow output?

Annual electricity figures and room square-footage ceilings below reflect Anzzi EF-AZ101WH tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Anzzi EF-AZ101WH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 61 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 132.3 kWh/yr (~$21.17/yr) | 15.1 W x 8,760 hrs / 1,000 |

## Which competing models share Anzzi EF-AZ101WH airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Aria QBV0800**](https://siematic-charleston.com/ventilation-fans/aria-qbv0800/) | 80 / 68.9 CFM | 0.7 sones (Same) | 5.3 CFM/W | 4 in. diameter |
| [**Haier QVE801DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve801dtww/) | 80 / 68.9 CFM | 0.7 sones (Same) | 5.3 CFM/W | 4 in. diameter |
| [**Canarm CNP80**](https://siematic-charleston.com/ventilation-fans/canarm-cnp80/) | 80 / 62.6 CFM | 0.7 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| [**ACIQ AES80**](https://siematic-charleston.com/ventilation-fans/aciq-aes80/) | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**CFM TF80N**](https://siematic-charleston.com/ventilation-fans/cfm-tf80n/) | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |

## How much airflow margin does Anzzi EF-AZ101WH give your bath?

Run a quick local room-volume check for Anzzi EF-AZ101WH by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Anzzi EF-AZ101WH?

Match Anzzi EF-AZ101WH directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 68 sq ft with 8-ft ceilings (61 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Anzzi EF-AZ101WH?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Anzzi EF-AZ101WH.

### What happens to Anzzi EF-AZ101WH CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Anzzi EF-AZ101WH moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Anzzi EF-AZ101WH sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, Anzzi EF-AZ101WH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Anzzi EF-AZ101WH cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Anzzi EF-AZ101WH 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Anzzi EF-AZ101WH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ101WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Anzzi EF-AZ101WH?

Anzzi EF-AZ101WH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Anzzi EF-AZ101WH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ101WH's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Anzzi EF-AZ101WH ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ101WH covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Anzzi EF-AZ101WH run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Anzzi EF-AZ101WH.

## Which GradeMark tools pair best with Anzzi EF-AZ101WH?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Anzzi EF-AZ101WH.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Aria QBV0800 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aria-qbv0800/)
- [Broan AE80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80-2369236/)
- [Air King AK80LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)