title: "Anzzi EF-AZ108WH Bath Fan (100 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/anzzi-ef-az108wh/
description: "ENERGY STAR specs for Anzzi EF-AZ108WH: 100 CFM, 2.0 sones (#522 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Anzzi EF-AZ108WH Exhaust Fan Specifications

ENERGY STAR PD #3425444 · Bathroom/Utility Room · Qualified 2024-03-15

Verified Specification Summary

Homeowners specifying Anzzi EF-AZ108WH gain 100 CFM at 0.1 in. w.g. (92.2 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 92 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ108WH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 92.2 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 92.2% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Anzzi EF-AZ108WH vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.2 CFM out of 100 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3425444 verifies EF-AZ108WH (series: EF) under Anzzi (8 listed models, qualified 2024-03-15). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include ACIQ AP100 (100.0 CFM) and Air King FR100 (100.0 CFM).

## What acoustic percentile does Anzzi EF-AZ108WH occupy among 1,145 bath blowers?

Inspect how Anzzi EF-AZ108WH positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Anzzi EF-AZ108WH best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Anzzi EF-AZ108WH housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Anzzi EF-AZ108WH acoustic and static metrics stand?

Compare Anzzi EF-AZ108WH published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Anzzi (8 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | EF-AZ108WH / EF | PD ID 3425444 (Qualified 2024-03-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (92.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Can Anzzi EF-AZ108WH handle taller ceilings or walk-in tub steam?

Evaluate how Anzzi EF-AZ108WH scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Anzzi EF-AZ108WH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Anzzi EF-AZ108WH?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AP100**](https://siematic-charleston.com/ventilation-fans/aciq-ap100/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Air King FR100**](https://siematic-charleston.com/ventilation-fans/air-king-fr100/) | 100 / 82.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Aria QBV01000**](https://siematic-charleston.com/ventilation-fans/aria-qbv01000/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Cyclone CT100**](https://siematic-charleston.com/ventilation-fans/cyclone-ct100/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7105-12-BN**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-12-bn/) | 100 / 75.4 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## Is Anzzi EF-AZ108WH sized right for your shower or tub room?

Check whether Anzzi EF-AZ108WH clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Anzzi EF-AZ108WH fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Anzzi EF-AZ108WH.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 42 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 92.2 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Anzzi EF-AZ108WH?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Anzzi EF-AZ108WH.

### Does running Anzzi EF-AZ108WH continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Anzzi EF-AZ108WH draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Anzzi EF-AZ108WH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ108WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Anzzi EF-AZ108WH?

Anzzi EF-AZ108WH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Anzzi EF-AZ108WH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ108WH's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Anzzi EF-AZ108WH code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ108WH clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Anzzi EF-AZ108WH?

Do not force Anzzi EF-AZ108WH into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Anzzi EF-AZ108WH retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Anzzi EF-AZ108WH produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Anzzi EF-AZ108WH disturb adjacent bedrooms during night use?

Acoustic measurement places Anzzi EF-AZ108WH at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## How can you cross-check Anzzi EF-AZ108WH against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Anzzi EF-AZ108WH.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Aria QBV01000 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aria-qbv01000/)
- [Cyclone CT100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-ct100/)
- [Anzzi EF-AZ107WH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az107wh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)