title: "Aprilaire 8144NC Bath Fan (124 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aprilaire-8144nc/
description: "ENERGY STAR specs for Aprilaire 8144NC: 124 CFM, 5.1 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Aprilaire 8144NC Exhaust Fan Specifications

ENERGY STAR PD #4667276 · In-line (multi-port) · Qualified 2026-07-08

Verified Specification Summary

Tested under HVI protocols, the Aprilaire 8144NC exhaust unit achieves 124 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 5.1 CFM/W efficacy, covering standard baths up to 124 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aprilaire 8144NC Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 124 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.1 CFM/W (#507/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 24.3 W (8.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Aprilaire 8144NC vs. 1,145-Model ENERGY STAR Benchmarks show?

Aprilaire 8144NC (EPA filing PD #4667276) omits a published 0.1-inch sone acoustic rating in its current In-line (multi-port) certification record.

Free-discharge delivery reaches 124 CFM (#287 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4667276 verifies 8144NC (series: 8144NC) under Aprilaire (3 listed models, qualified 2026-07-08). Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 24.3 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 212.9 kWh/yr (~$34.06/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

## What attic duct routing preserves Aprilaire 8144NC CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Aprilaire 8144NC, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Aprilaire 8144NC measure up on airflow and noise ratings?

Each row below breaks down Aprilaire 8144NC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Aprilaire (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 8144NC / 8144NC | PD ID 4667276 (Qualified 2026-07-08) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (124 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Aprilaire 8144NC CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Aprilaire 8144NC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 124 sq ft | 1 CFM/sq ft @ 124 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 74 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.9 kWh/yr (~$34.06/yr) | 24.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Aprilaire 8144NC?

Compare Aprilaire 8144NC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |

## Can you size Aprilaire 8144NC for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Aprilaire 8144NC verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Aprilaire 8144NC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Aprilaire 8144NC carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 124 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 124 sq ft
- **Works well for:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Aprilaire 8144NC?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Aprilaire 8144NC.

### How does Aprilaire 8144NC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Aprilaire 8144NC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Aprilaire 8144NC?

Rule out Aprilaire 8144NC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Aprilaire 8144NC capacity?

Because static drag at 0.25 in. w.g. lowers Aprilaire 8144NC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Aprilaire 8144NC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Aprilaire 8144NC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Aprilaire 8144NC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Aprilaire 8144NC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Aprilaire 8144NC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aprilaire 8144NC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Aprilaire 8144NC?

Aprilaire 8144NC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Aprilaire 8144NC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aprilaire 8144NC's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Aprilaire 8144NC?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Aprilaire 8144NC.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [BSH Home Appliances Corporation HCP30E51UC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/bsh-home-appliances-corporation-hcp30e51uc/)
- [Air King ESQZ2308 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esqz2308/)
- [Whirlpool Corporation WVU7130JS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/whirlpool-corporation-wvu7130js/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)