Verified Specification Summary

Tested under HVI protocols, the Aprilaire 8145 exhaust unit achieves 190 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, covering standard baths up to 190 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aprilaire 8145 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 190 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 43.2 W (15.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Aprilaire 8145 vs. 1,145-Model ENERGY STAR Benchmarks show?

Aprilaire 8145 (EPA filing PD #4667277) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 190 CFM (#64 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4667277 verifies 8145 (series: 8145) under Aprilaire (3 listed models, qualified 2026-07-08). Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 43.2 watts, about 15.8 kWh/yr (~$2.53/yr at $0.16/kWh) for 1 hr/day shower timers or 378.4 kWh/yr (~$60.54/yr) continuously. Closest competing matches include Zephyr AK8400BS-ES (190.0 CFM) and Broan ALT4306SS (190.0 CFM).

## What attic duct routing preserves Aprilaire 8145 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Aprilaire 8145, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Aprilaire 8145 measure up on airflow and noise ratings?

Each row below breaks down Aprilaire 8145 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Aprilaire (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 8145 / 8145 | PD ID 4667277 (Qualified 2026-07-08) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (190 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Aprilaire 8145 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Aprilaire 8145

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 190 sq ft | 1 CFM/sq ft @ 190 CFM |
| Tall Bath (9-ft Ceiling) | Up to 168 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 140 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.8 kWh/yr (~$2.53/yr) | 43.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 378.4 kWh/yr (~$60.54/yr) | 43.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Aprilaire 8145?

Compare Aprilaire 8145 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Zephyr AK8400BS-ES**](https://siematic-charleston.com/ventilation-fans/zephyr-ak8400bs-es/) | 190 / N/A CFM | 2.0 sones | 3.9 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss-4481124/) | 190 / N/A CFM | Unpublished | 3.7 CFM/W | 3.25 x 14 in. rectangular |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Broan L200EL**](https://siematic-charleston.com/ventilation-fans/broan-l200el/) | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |

## Can you size Aprilaire 8145 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Aprilaire 8145 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Aprilaire 8145 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Aprilaire 8145.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 190 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 190 sq ft
- **Target scenario:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Aprilaire 8145?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Aprilaire 8145.

### Will Aprilaire 8145 disturb adjacent bedrooms during night use?

Acoustic measurement places Aprilaire 8145 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Aprilaire 8145 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Aprilaire 8145 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Aprilaire 8145 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aprilaire 8145's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Aprilaire 8145?

Aprilaire 8145 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Aprilaire 8145's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aprilaire 8145's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Aprilaire 8145 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Aprilaire 8145 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Aprilaire 8145?

Do not force Aprilaire 8145 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Aprilaire 8145 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Aprilaire 8145 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

## What neighboring pages and tools support Aprilaire 8145?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Aprilaire 8145.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Aprilaire 8145NC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aprilaire-8145nc/)
- [Broan ALT4306SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss-4481124/)
- [Zephyr ZSI-E36BS-ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/zephyr-zsi-e36bs-es/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)