title: "Aria QBV01000 Bath Fan (100 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aria-qbv01000/
description: "ENERGY STAR specs for Aria QBV01000: 100 CFM, 2.0 sones (#522 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Aria QBV01000 Exhaust Fan Specifications

ENERGY STAR PD #3984070 · Bathroom/Utility Room · Qualified 2025-01-10

Verified Specification Summary

Certified by EPA ENERGY STAR, Aria QBV01000 delivers 100 CFM free-air (92.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 92 sq ft (8-ft height) or 81 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aria QBV01000 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 92.2 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 92.2% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Aria QBV01000 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.2 CFM out of 100 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places QBV01000 (series: QBV) (PD #3984070) among 3 Aria entries qualified through 2025-01-10. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include ACIQ AP100 (100.0 CFM) and Air King FR100 (100.0 CFM).

## How noisy is Aria QBV01000 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Aria QBV01000 measures 2.0 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Aria QBV01000 airflow?

Connecting Aria QBV01000 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Aria QBV01000 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Aria QBV01000 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Aria (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | QBV01000 / QBV | PD ID 3984070 (Qualified 2025-01-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (92.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Aria QBV01000?

Calculated coverage metrics translate Aria QBV01000 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Aria QBV01000

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Aria QBV01000?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AP100**](https://siematic-charleston.com/ventilation-fans/aciq-ap100/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Air King FR100**](https://siematic-charleston.com/ventilation-fans/air-king-fr100/) | 100 / 82.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ107WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az107wh/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ108WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az108wh/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Cyclone CT100**](https://siematic-charleston.com/ventilation-fans/cyclone-ct100/) | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## Does Aria QBV01000 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Aria QBV01000 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Aria QBV01000 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Aria QBV01000.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 42 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 92.2 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Aria QBV01000?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Aria QBV01000.

### Is Aria QBV01000 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Aria QBV01000 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Aria QBV01000?

Do not force Aria QBV01000 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Aria QBV01000 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Aria QBV01000 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Aria QBV01000 disturb adjacent bedrooms during night use?

Acoustic measurement places Aria QBV01000 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Aria QBV01000 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Aria QBV01000 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Aria QBV01000 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aria QBV01000's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Aria QBV01000?

Aria QBV01000 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Aria QBV01000's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aria QBV01000's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Aria QBV01000?

Use the related reference pages and estimators below to cross-check Aria QBV01000 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Cyclone CT100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-ct100/)
- [HomeWerks Worldwide 7105-12-BN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-12-bn/)
- [Anzzi EF-AZ108WH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az108wh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)