Homeowners specifying Aria QBV0800 gain 80 CFM at 0.1 in. w.g. (68.9 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 5.3 CFM/W efficacy, venting bathrooms up to 68 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aria QBV0800 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 5.3 CFM/W (#494/1,145)

- **Static Retention**: 86.1% @ 0.25"

- **Motor Draw**: 15.1 W (5.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Aria QBV0800 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.9 CFM out of 80 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Aria registers 3 certified models, with SKU QBV0800 (series: QBV) (PD #3984071) certified since 2025-01-10. Lighting kit: No. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.1 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 132.3 kWh/yr (~$21.17/yr) continuously. Closest competing matches include Anzzi EF-AZ101WH (80.0 CFM) and Haier QVE801DTWW (80.0 CFM).

## What acoustic percentile does Aria QBV0800 occupy among 1,145 bath blowers?

Inspect how Aria QBV0800 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Aria QBV0800 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Aria QBV0800 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Aria QBV0800 acoustic and static metrics stand?

Compare Aria QBV0800 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Aria (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | QBV0800 / QBV | PD ID 3984071 (Qualified 2025-01-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Aria QBV0800 handle taller ceilings or walk-in tub steam?

Evaluate how Aria QBV0800 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Aria QBV0800

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 61 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 132.3 kWh/yr (~$21.17/yr) | 15.1 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Aria QBV0800?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Anzzi EF-AZ101WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az101wh/) | 80 / 68.9 CFM | 0.7 sones (Same) | 5.3 CFM/W | 4 in. diameter |
| [**Haier QVE801DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve801dtww/) | 80 / 68.9 CFM | 0.7 sones (Same) | 5.3 CFM/W | 4 in. diameter |
| [**Canarm CNP80**](https://siematic-charleston.com/ventilation-fans/canarm-cnp80/) | 80 / 62.6 CFM | 0.7 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| [**ACIQ AES80**](https://siematic-charleston.com/ventilation-fans/aciq-aes80/) | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**CFM TF80N**](https://siematic-charleston.com/ventilation-fans/cfm-tf80n/) | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |

## Is Aria QBV0800 sized right for your shower or tub room?

Check whether Aria QBV0800 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Aria QBV0800 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Aria QBV0800.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 68.9 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Aria QBV0800?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Aria QBV0800.

### Which bathroom layouts should pick a larger blower than Aria QBV0800?

Do not force Aria QBV0800 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Aria QBV0800 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Aria QBV0800 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Aria QBV0800 disturb adjacent bedrooms during night use?

Acoustic measurement places Aria QBV0800 at 0.7 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Aria QBV0800 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Aria QBV0800 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Aria QBV0800 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aria QBV0800's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Aria QBV0800?

Aria QBV0800 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Aria QBV0800's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aria QBV0800's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Aria QBV0800 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Aria QBV0800 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## How can you cross-check Aria QBV0800 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Aria QBV0800.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80-2369236/)
- [Broan AE80B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80b/)
- [Anzzi EF-AZ101WH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az101wh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)