#  AUPU AV11AL2 Exhaust Fan Specifications

ENERGY STAR PD #2333324 · Bathroom/Utility Room · Qualified 2019-02-08

Verified Specification Summary

Tested under HVI protocols, the AUPU AV11AL2 exhaust unit achieves 110 CFM at 0.1 in. w.g. (89 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 4.4 CFM/W efficacy, covering standard baths up to 89 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AV11AL2 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 89 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 80.9% @ 0.25"

- **Motor Draw**: 25.0 W (9.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AUPU AV11AL2 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89 CFM at 0.25 in. w.g. (80.9% retention, 6.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: AUPU registers 35 certified models, with SKU AV11AL2 (series: AV) (PD #2333324) certified since 2019-02-08. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include AERO PURE ABF110L5W (110.0 CFM) and Tech Drive TD-BF-07 (110.0 CFM).

## Where do AUPU AV11AL2 sones rank across EPA ENERGY STAR fans?

Comparing AUPU AV11AL2 (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves AUPU AV11AL2 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU AV11AL2, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does AUPU AV11AL2 measure up on airflow and noise ratings?

Each row below breaks down AUPU AV11AL2 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AUPU (35 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AV11AL2 / AV | PD ID 2333324 (Qualified 2019-02-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (89 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect AUPU AV11AL2 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AUPU AV11AL2

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against AUPU AV11AL2?

Compare AUPU AV11AL2 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**AERO PURE ABF110L5W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110l5w/) | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-07**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-07/) | 110 / 100.2 CFM | 0.8 sones (+0.10) | 3.8 CFM/W | 6 in. diameter |
| [**Broan RB110L1**](https://siematic-charleston.com/ventilation-fans/broan-rb110l1/) | 110 / 95.7 CFM | 0.8 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Greenheck SP-A125**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a125/) | 109 / N/A CFM | 0.7 sones (Same) | 5.8 CFM/W | 6 x 8 in. rectangular |
| [**ACIQ ANP100**](https://siematic-charleston.com/ventilation-fans/aciq-anp100/) | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |

## Can you size AUPU AV11AL2 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU AV11AL2 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out AUPU AV11AL2?

Compare where AUPU AV11AL2 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 89 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 0.7 sones up to 89 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to AUPU AV11AL2?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU AV11AL2.

### Is AUPU AV11AL2 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can AUPU AV11AL2 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AV11AL2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AUPU AV11AL2?

AUPU AV11AL2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AUPU AV11AL2's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AV11AL2's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can AUPU AV11AL2 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AUPU AV11AL2 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap AUPU AV11AL2 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU AV11AL2 lacks adequate reserve.

### How does AUPU AV11AL2 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU AV11AL2 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is AUPU AV11AL2 quiet enough for a primary bedroom bathroom?

At 0.7 sones, AUPU AV11AL2 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## What neighboring pages and tools support AUPU AV11AL2?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around AUPU AV11AL2.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-A125 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a125/)
- [KORA SBF90DC-MS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf90dc-ms/)
- [AUPU AV11AL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-av11al1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)