---
title: "AUPU B6-11F Bath Fan (110 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aupu-b6-11f/
description: "ENERGY STAR specs for AUPU B6-11F: 110 CFM, 0.8 sones (#194 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  AUPU B6-11F Exhaust Fan Specifications

ENERGY STAR PD #4727674 · Bathroom/Utility Room · Qualified 2026-11-04

Verified Specification Summary

Rated for 110 CFM open-air (99.9 CFM at 0.25 in. w.g.), AUPU B6-11F registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 99 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-11F Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 99.9 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 90.8% @ 0.25"

- **Motor Draw**: 28.2 W (10.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AUPU B6-11F vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99.9 CFM out of 110 CFM (90.8% retention, 3.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B6-11F (series: Flush) (PD #4727674) among 35 AUPU entries qualified through 2026-11-04. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Tech Drive TD-BF-07 (110.0 CFM) and Broan RB110L1 (110.0 CFM).

## How does AUPU B6-11F acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against AUPU B6-11F (0.8 sones).

## How do flex elbows choke AUPU B6-11F at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps AUPU B6-11F moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does AUPU B6-11F meet residential exhaust fan code specs?

Inspect AUPU B6-11F mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AUPU (35 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | B6-11F / Flush | PD ID 4727674 (Qualified 2026-11-04) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (99.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match AUPU B6-11F airflow output?

Annual electricity figures and room square-footage ceilings below reflect AUPU B6-11F tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for AUPU B6-11F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |

## Which competing models share AUPU B6-11F airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-07**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-07/) | 110 / 100.2 CFM | 0.8 sones (Same) | 3.8 CFM/W | 6 in. diameter |
| [**Broan RB110L1**](https://siematic-charleston.com/ventilation-fans/broan-rb110l1/) | 110 / 95.7 CFM | 0.8 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| [**ACIQ AEP110**](https://siematic-charleston.com/ventilation-fans/aciq-aep110/) | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| [**Canarm CEP110**](https://siematic-charleston.com/ventilation-fans/canarm-cep110/) | 110 / 94.2 CFM | 0.9 sones (+0.10) | 4.2 CFM/W | 6 in. diameter |
| [**Cyclone ESCBP110**](https://siematic-charleston.com/ventilation-fans/cyclone-escbp110/) | 110 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |

## How much airflow margin does AUPU B6-11F give your bath?

Run a quick local room-volume check for AUPU B6-11F by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does AUPU B6-11F suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU B6-11F for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 49 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 99 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about AUPU B6-11F?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to AUPU B6-11F.

### Does AUPU B6-11F pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-11F easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install AUPU B6-11F in a bathroom remodel?

Avoid specifying AUPU B6-11F in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut AUPU B6-11F airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU B6-11F achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does AUPU B6-11F occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., AUPU B6-11F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does AUPU B6-11F add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, AUPU B6-11F averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can AUPU B6-11F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-11F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AUPU B6-11F?

AUPU B6-11F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AUPU B6-11F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-11F's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with AUPU B6-11F?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to AUPU B6-11F.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AUPU B6-11L1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-11l1/)
- [AUPU BF6-11 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-bf6-11/)
- [AUPU B6-13S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13s/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
