#  AUPU B6-11HF Exhaust Fan Specifications

ENERGY STAR PD #4727654 · Bathroom/Utility Room · Qualified 2026-11-04

Verified Specification Summary

The AUPU B6-11HF (Flush) moves 110 CFM at 0.1 in. w.g. (89.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.7 CFM/W efficacy, sizing bathrooms up to 89 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-11HF Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 89.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.7 CFM/W (#201/1,145)

- **Static Retention**: 81.4% @ 0.25"

- **Motor Draw**: 11.3 W (4.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AUPU B6-11HF vs. 1,145-Model ENERGY STAR Benchmarks show?

AUPU B6-11HF (EPA filing PD #4727654) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.5 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

AUPU maintains 35 active ENERGY STAR blowers; B6-11HF (series: Flush) (PD #4727654) gained qualification on 2026-11-04. Lighting kit: No. At 9.7 CFM/W (#201 of 1,145, top 17.9% of 1,145 rated models, more efficient than 82.1% of rated models, 5.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.3 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 99.0 kWh/yr (~$15.84/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How does duct geometry alter AUPU B6-11HF static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to AUPU B6-11HF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for AUPU B6-11HF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AUPU (35 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | B6-11HF / Flush | PD ID 4727654 (Qualified 2026-11-04) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (89.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can AUPU B6-11HF ventilate safely?

Sizing outputs below convert AUPU B6-11HF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for AUPU B6-11HF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.0 kWh/yr (~$15.84/yr) | 11.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match AUPU B6-11HF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Will AUPU B6-11HF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether AUPU B6-11HF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does AUPU B6-11HF fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering AUPU B6-11HF.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 39 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 89 sq ft with 8-ft ceilings (79 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern AUPU B6-11HF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting AUPU B6-11HF.

### Is AUPU B6-11HF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), AUPU B6-11HF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than AUPU B6-11HF?

Do not force AUPU B6-11HF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does AUPU B6-11HF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, AUPU B6-11HF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will AUPU B6-11HF disturb adjacent bedrooms during night use?

Acoustic measurement places AUPU B6-11HF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running AUPU B6-11HF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of AUPU B6-11HF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can AUPU B6-11HF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-11HF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AUPU B6-11HF?

AUPU B6-11HF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AUPU B6-11HF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-11HF's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to AUPU B6-11HF?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for AUPU B6-11HF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AUPU B6-11HL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-11hl1/)
- [AUPU B6-11HR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-11hr/)
- [AUPU AVS0511DL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-avs0511dl3/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)