#  AUPU B6-13 Exhaust Fan Specifications

ENERGY STAR PD #4688994 · Bathroom/Utility Room · Qualified 2026-08-05

Verified Specification Summary

Certified by EPA ENERGY STAR, AUPU B6-13 delivers 130 CFM free-air (113.6 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 113 sq ft (8-ft height) or 100 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-13 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 113.6 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 87.4% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AUPU B6-13 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.6 CFM out of 130 CFM (87.4% retention, 0.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B6-13 (series: VF6) (PD #4688994) among 35 AUPU entries qualified through 2026-08-05. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and Ortech OD-1209PB (120.0 CFM).

## How noisy is AUPU B6-13 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU B6-13 measures 0.8 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect AUPU B6-13 airflow?

Connecting AUPU B6-13 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify AUPU B6-13 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU B6-13 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AUPU (35 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | B6-13 / VF6 | PD ID 4688994 (Qualified 2026-08-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (113.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit AUPU B6-13?

Calculated coverage metrics translate AUPU B6-13 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AUPU B6-13

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to AUPU B6-13?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Milano TY-130-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-130-e/) | 130 / 106.3 CFM | 0.7 sones (-0.10) | 4.1 CFM/W | 6 in. diameter |
| [**Ortech OD-1209PB**](https://siematic-charleston.com/ventilation-fans/ortech-od-1209pb/) | 120 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Dayton 3DPE5B**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe5b/) | 130 / N/A CFM | 0.7 sones (-0.10) | 5.8 CFM/W | 6 x 8 in. rectangular |
| [**Hampton Bay 7136-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7136-02/) | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |
| [**HomeWerks Worldwide 7136-02HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7136-02hw/) | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |

## Does AUPU B6-13 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU B6-13 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install AUPU B6-13 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU B6-13 for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 63 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 113.6 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for AUPU B6-13?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU B6-13.

### When is AUPU B6-13 undersized or poorly matched for a bath renovation?

Skip AUPU B6-13 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check AUPU B6-13 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU B6-13 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does AUPU B6-13 sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, AUPU B6-13 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define AUPU B6-13?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can AUPU B6-13 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-13's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AUPU B6-13?

AUPU B6-13 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AUPU B6-13's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-13's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does AUPU B6-13 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU B6-13 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Where can you explore more benchmarks around AUPU B6-13?

Use the related reference pages and estimators below to cross-check AUPU B6-13 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AUPU B6-13L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13l/)
- [AUPU B6-13S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13s/)
- [Revent RVLH150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvlh150/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)