title: "AUPU B6-13L Bath Fan (130 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/aupu-b6-13l/
description: "ENERGY STAR specs for AUPU B6-13L: 130 CFM, 0.8 sones (#194 of 607), 3.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  AUPU B6-13L Exhaust Fan Specifications

ENERGY STAR PD #4688954 · Bathroom/Utility Room · Qualified 2026-08-05

Verified Specification Summary

In EPA dataset 8dv7-nngq, AUPU B6-13L tests at 130 CFM free discharge (110.2 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 110 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-13L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 110.2 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 84.8% @ 0.25"

- **Motor Draw**: 34.2 W (12.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does AUPU B6-13L vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 110.2 CFM at 0.25 in. w.g. (84.8% retention, 2.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4688954 verifies B6-13L (series: VF6) under AUPU (35 listed models, qualified 2026-08-05). Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.2 watts, about 12.5 kWh/yr (~$2.00/yr at $0.16/kWh) for 1 hr/day shower timers or 299.6 kWh/yr (~$47.94/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and Ortech OD-1209PB (120.0 CFM).

## Does AUPU B6-13L fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AUPU B6-13L at 0.8 sones.

## Why avoid unvented attic termination with AUPU B6-13L?

Under ASHRAE 62.2 best practice, AUPU B6-13L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern AUPU B6-13L?

Before cutting ceiling drywall or sizing attic transitions for AUPU B6-13L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | AUPU (35 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | B6-13L / VF6 | PD ID 4688954 (Qualified 2026-08-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (110.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit AUPU B6-13L?

Bathroom ventilation sizing below maps AUPU B6-13L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for AUPU B6-13L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.5 kWh/yr (~$2.00/yr) | 34.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 299.6 kWh/yr (~$47.94/yr) | 34.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest AUPU B6-13L in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AUPU B6-13L.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Milano TY-130-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-130-e/) | 130 / 106.3 CFM | 0.7 sones (-0.10) | 4.1 CFM/W | 6 in. diameter |
| [**Ortech OD-1209PB**](https://siematic-charleston.com/ventilation-fans/ortech-od-1209pb/) | 120 / 101.6 CFM | 0.9 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Hampton Bay 7136-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7136-02/) | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |
| [**HomeWerks Worldwide 7136-02HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7136-02hw/) | 140 / 124.4 CFM | 1.0 sones (+0.20) | 3.9 CFM/W | 6 in. diameter |
| [**Dayton 3DPE5B**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe5b/) | 130 / N/A CFM | 0.7 sones (-0.10) | 5.8 CFM/W | 6 x 8 in. rectangular |

## What percentage of room demand does AUPU B6-13L cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AUPU B6-13L tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying AUPU B6-13L?

Match AUPU B6-13L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 110.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 0.8 sones up to 110 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for AUPU B6-13L?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AUPU B6-13L.

### Where does AUPU B6-13L sit on acoustic comfort for senior homeowners?

Measuring 0.8 sones, AUPU B6-13L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does AUPU B6-13L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running AUPU B6-13L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can AUPU B6-13L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-13L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing AUPU B6-13L?

AUPU B6-13L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change AUPU B6-13L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-13L's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can AUPU B6-13L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-13L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does AUPU B6-13L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with AUPU B6-13L.

### What happens to AUPU B6-13L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, AUPU B6-13L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## What related resources expand on AUPU B6-13L?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AUPU B6-13S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13s/)
- [AUPU B6-11F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-11f/)
- [AUPU B6-13 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-b6-13/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)