---
title: "Best HBN554212SS Bath Fan (200 CFM, 0.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/best-hbn554212ss/
description: "ENERGY STAR specs for Best HBN554212SS: 200 CFM, 0.0 sones (#1 of 607), 16.6 CFM/W, 10 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Best HBN554212SS Exhaust Fan Specifications

ENERGY STAR PD #3998916 · Range Hood · Qualified 2025-02-21

Verified Specification Summary

The Best HBN554212SS (RANGE HOOD) moves 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #1 of 607 in quietness (0.0 sones), and delivers 16.6 CFM/W efficacy, sizing bathrooms up to 200 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best HBN554212SS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 200 / N/A CFM

- **Noise @ 0.1"**: 0.0 sones (#1/607)

- **Efficacy Rank**: 16.6 CFM/W (#4/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 12.0 W (4.4 kWh/yr)

- **Duct & Tier**: 10 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Best HBN554212SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.0 sones (#1 of 607 rated models, quietest 1.5% of 607 rated models, quieter than 98.5% of rated models, 1.00 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 10 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 10 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Best maintains 17 active ENERGY STAR blowers; HBN554212SS (series: RANGE HOOD) (PD #3998916) gained qualification on 2025-02-21. Lighting kit: Yes. At 16.6 CFM/W (#4 of 1,145, top 1.0% of 1,145 rated models, more efficient than 99.0% of rated models, 11.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Best HBN536212SS (200.0 CFM) and Best HBN536912SS (200.0 CFM).

## Where does Best HBN554212SS sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Best HBN554212SS static pressure?

Smooth 10 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Best HBN554212SS?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Best HBN554212SS alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Best (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | HBN554212SS / RANGE HOOD | PD ID 3998916 (Qualified 2025-02-21) |
| **Duct Connection** | 10 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (200 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Best HBN554212SS ventilate safely?

Sizing outputs below convert Best HBN554212SS tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Best HBN554212SS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 200 sq ft | 1 CFM/sq ft @ 200 CFM |
| Tall Bath (9-ft Ceiling) | Up to 177 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 150 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.4 kWh/yr (~$0.70/yr) | 12.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 105.1 kWh/yr (~$16.82/yr) | 12.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Best HBN554212SS closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Best HBN536212SS**](https://siematic-charleston.com/ventilation-fans/best-hbn536212ss/) | 200 / N/A CFM | 0.0 sones (Same) | 16.6 CFM/W | 10 in. diameter |
| [**Best HBN536912SS**](https://siematic-charleston.com/ventilation-fans/best-hbn536912ss/) | 200 / N/A CFM | 0.0 sones (Same) | 16.6 CFM/W | 10 in. diameter |
| [**Best HBN542912SS**](https://siematic-charleston.com/ventilation-fans/best-hbn542912ss/) | 200 / N/A CFM | 0.0 sones (Same) | 16.6 CFM/W | 10 in. diameter |
| [**Best HBN548212SS**](https://siematic-charleston.com/ventilation-fans/best-hbn548212ss/) | 200 / N/A CFM | 0.0 sones (Same) | 16.6 CFM/W | 10 in. diameter |
| [**Best HBN548912SS**](https://siematic-charleston.com/ventilation-fans/best-hbn548912ss/) | 200 / N/A CFM | 0.0 sones (Same) | 16.6 CFM/W | 10 in. diameter |

## Will Best HBN554212SS clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Best HBN554212SS satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Best HBN554212SS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Best HBN554212SS carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 150 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 200 sq ft with 8-ft ceilings (177 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 10 in. diameter

## What key rules and numbers govern Best HBN554212SS?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Best HBN554212SS.

### What duct and room conditions disqualify Best HBN554212SS?

Rule out Best HBN554212SS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Best HBN554212SS capacity?

Because static drag at 0.25 in. w.g. lowers Best HBN554212SS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 10 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Best HBN554212SS compared with a standard 3.0 sone builder fan?

Tested at 0.0 sones, Best HBN554212SS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Best HBN554212SS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Best HBN554212SS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Best HBN554212SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best HBN554212SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Best HBN554212SS?

Best HBN554212SS features a 10 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Best HBN554212SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best HBN554212SS's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Best HBN554212SS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Best HBN554212SS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Which guides and calculators connect next to Best HBN554212SS?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Best HBN554212SS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Best HBN560212SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn560212ss/)
- [Best HBN566212SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn566212ss/)
- [Best HBN548912SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn548912ss/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
