#  Best UCB3I30SBS Exhaust Fan Specifications

ENERGY STAR PD #2336465 · Range Hood · Qualified 2019-03-08

Verified Specification Summary

The Best UCB3I30SBS (UCB3I) moves 160 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.2 CFM/W efficacy, sizing bathrooms up to 160 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best UCB3I30SBS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 160 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.2 CFM/W (#1,091/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 50.0 W (18.2 kWh/yr)

- **Duct & Tier**: 3.25 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Best UCB3I30SBS vs. 1,145-Model ENERGY STAR Benchmarks show?

Best UCB3I30SBS (EPA filing PD #2336465) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 3.25 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Best's 17-unit lineup, UCB3I30SBS (series: UCB3I) carries PD #2336465 dating to 2019-03-08. Lighting kit: Yes. At 3.2 CFM/W (#1,091 of 1,145, below median tier among 1,145 rated models; more efficient than 4.0% of rated models, 1.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).

## How does duct geometry alter Best UCB3I30SBS static pressure?

Smooth 3.25 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Best UCB3I30SBS?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Best UCB3I30SBS alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Best (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | UCB3I30SBS / UCB3I | PD ID 2336465 (Qualified 2019-03-08) |
| **Duct Connection** | 3.25 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Best UCB3I30SBS ventilate safely?

Sizing outputs below convert Best UCB3I30SBS tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Best UCB3I30SBS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 18.2 kWh/yr (~$2.91/yr) | 50.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 438.0 kWh/yr (~$70.08/yr) | 50.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Best UCB3I30SBS closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss-4481125/) | 160 / N/A CFM | Unpublished | 3.1 CFM/W | 3.25 x 10 in. rectangular |

## Will Best UCB3I30SBS clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Best UCB3I30SBS satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Best UCB3I30SBS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Best UCB3I30SBS carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 3.25 in. diameter

## What key rules and numbers govern Best UCB3I30SBS?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Best UCB3I30SBS.

### How loud is Best UCB3I30SBS compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Best UCB3I30SBS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Best UCB3I30SBS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Best UCB3I30SBS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Best UCB3I30SBS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best UCB3I30SBS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Best UCB3I30SBS?

Best UCB3I30SBS features a 3.25 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Best UCB3I30SBS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best UCB3I30SBS's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Best UCB3I30SBS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Best UCB3I30SBS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Best UCB3I30SBS?

Rule out Best UCB3I30SBS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Best UCB3I30SBS capacity?

Because static drag at 0.25 in. w.g. lowers Best UCB3I30SBS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3.25 in. diameter rigid ducting straight to a dedicated exterior damper.

## Which guides and calculators connect next to Best UCB3I30SBS?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Best UCB3I30SBS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Best UCB3I30SBW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-ucb3i30sbw/)
- [Broan ALT3304SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-alt3304ss/)
- [Best UCB3I30SBN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-ucb3i30sbn/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)