title: "Broan 744FL Bath Fan (70 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-744fl/
description: "ENERGY STAR specs for Broan 744FL: 70 CFM, 1.5 sones (#412 of 607), 4.0 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Broan 744FL Exhaust Fan Specifications

ENERGY STAR PD #2249117 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan 744FL tests at 70 CFM free discharge (58.3 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 58 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan 744FL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 58.3 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 83.3% @ 0.25"

- **Motor Draw**: 17.5 W (6.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan 744FL vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.3 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, 744FL (series: Recessed Fan Light) carries PD #2249117 dating to 2015-10-01. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Tech Drive FA-BF-02-L (70.0 CFM) and Commercial Electric 7130-18-CE (80.0 CFM).

## Does Broan 744FL fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan 744FL at 1.5 sones.

## Why avoid unvented attic termination with Broan 744FL?

Under ASHRAE 62.2 best practice, Broan 744FL needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Broan 744FL?

Before cutting ceiling drywall or sizing attic transitions for Broan 744FL, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 744FL / Recessed Fan Light | PD ID 2249117 (Qualified 2015-10-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (58.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Broan 744FL?

Bathroom ventilation sizing below maps Broan 744FL motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan 744FL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 153.3 kWh/yr (~$24.53/yr) | 17.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Broan 744FL in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan 744FL.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive FA-BF-02-L**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-02-l/) | 70 / 60.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 3 in. diameter |
| [**Commercial Electric 7130-18-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-18-ce/) | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan-Nutone BE8**](https://siematic-charleston.com/ventilation-fans/broan-nutone-be8/) | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Broan-Nutone BE8 = BEH with BE8F**](https://siematic-charleston.com/ventilation-fans/broan-nutone-be8-beh-with-be8f/) | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Broan-Nutone BEL8**](https://siematic-charleston.com/ventilation-fans/broan-nutone-bel8/) | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |

## What percentage of room demand does Broan 744FL cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan 744FL tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan 744FL in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan 744FL for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 58.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 1.5 sones up to 58 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Broan 744FL?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan 744FL.

### When is Broan 744FL undersized or poorly matched for a bath renovation?

Skip Broan 744FL if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Broan 744FL CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan 744FL registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Broan 744FL sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, Broan 744FL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan 744FL?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan 744FL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan 744FL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan 744FL?

Broan 744FL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan 744FL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan 744FL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan 744FL satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan 744FL clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## What related resources expand on Broan 744FL?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan 744LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744led/)
- [Tech Drive FA-BF-02-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-02-l/)
- [Broan 744 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)