#  Broan AE100B = A000HFNF with AE100BF1 Exhaust Fan Specifications

ENERGY STAR PD #4708498 · Bathroom/Utility Room · Qualified 2026-09-23

Verified Specification Summary

Tested under HVI protocols, the Broan AE100B = A000HFNF with AE100BF1 exhaust unit achieves 100 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 95 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE100B = A000HFNF with AE100BF1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 95.5 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 95.5% @ 0.25"

- **Motor Draw**: 23.3 W (8.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE100B = A000HFNF with AE100BF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 100 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4708498 verifies AE100B = A000HFNF with AE100BF1 (series: INVENT) under Broan (207 listed models, qualified 2026-09-23). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.3 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 204.1 kWh/yr (~$32.66/yr) continuously. Closest competing matches include Air King BFC100 (100.0 CFM) and Air King BFC100H (100.0 CFM).

## Where do Broan AE100B = A000HFNF with AE100BF1 sones rank across EPA ENERGY STAR fans?

Comparing Broan AE100B = A000HFNF with AE100BF1 (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Broan AE100B = A000HFNF with AE100BF1 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE100B = A000HFNF with AE100BF1, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan AE100B = A000HFNF with AE100BF1 measure up on airflow and noise ratings?

Each row below breaks down Broan AE100B = A000HFNF with AE100BF1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE100B = A000HFNF with AE100BF1 / INVENT | PD ID 4708498 (Qualified 2026-09-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan AE100B = A000HFNF with AE100BF1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AE100B = A000HFNF with AE100BF1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.5 kWh/yr (~$1.36/yr) | 23.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 204.1 kWh/yr (~$32.66/yr) | 23.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan AE100B = A000HFNF with AE100BF1?

Compare Broan AE100B = A000HFNF with AE100BF1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King BFC100**](https://siematic-charleston.com/ventilation-fans/air-king-bfc100/) | 100 / 86.5 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Air King BFC100H**](https://siematic-charleston.com/ventilation-fans/air-king-bfc100h/) | 100 / 86.5 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Good Housekeeping 84005**](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84005/) | 100 / 92.3 CFM | 1.0 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Air King AK100LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak100ls6/) | 100 / 82.7 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**Air King AK100LS6H**](https://siematic-charleston.com/ventilation-fans/air-king-ak100ls6h/) | 100 / 82.7 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |

## Can you size Broan AE100B = A000HFNF with AE100BF1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE100B = A000HFNF with AE100BF1 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan AE100B = A000HFNF with AE100BF1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE100B = A000HFNF with AE100BF1 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 95.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.0 sones up to 95 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Broan AE100B = A000HFNF with AE100BF1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE100B = A000HFNF with AE100BF1.

### How does Broan AE100B = A000HFNF with AE100BF1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE100B = A000HFNF with AE100BF1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Broan AE100B = A000HFNF with AE100BF1?

Rule out Broan AE100B = A000HFNF with AE100BF1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Broan AE100B = A000HFNF with AE100BF1 capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE100B = A000HFNF with AE100BF1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Broan AE100B = A000HFNF with AE100BF1 compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Broan AE100B = A000HFNF with AE100BF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Broan AE100B = A000HFNF with AE100BF1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE100B = A000HFNF with AE100BF1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan AE100B = A000HFNF with AE100BF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE100B = A000HFNF with AE100BF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE100B = A000HFNF with AE100BF1?

Broan AE100B = A000HFNF with AE100BF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE100B = A000HFNF with AE100BF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE100B = A000HFNF with AE100BF1's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Broan AE100B = A000HFNF with AE100BF1?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan AE100B = A000HFNF with AE100BF1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Good Housekeeping 84005 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84005/)
- [Air King BFC90 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfc90/)
- [Broan AE100B = A000HFKT with AE100BF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae100b-a000hfkt-with-ae100bf1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)