The Broan AE110K = A000HFKTC with AE110KF (INVENT) moves 110 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE110K = A000HFKTC with AE110KF Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 95.5 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 86.8% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE110K = A000HFKTC with AE110KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, AE110K = A000HFKTC with AE110KF (series: INVENT) carries PD #4708495 dating to 2026-09-23. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).

## Where does Broan AE110K = A000HFKTC with AE110KF sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Broan AE110K = A000HFKTC with AE110KF static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Broan AE110K = A000HFKTC with AE110KF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE110K = A000HFKTC with AE110KF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE110K = A000HFKTC with AE110KF / INVENT | PD ID 4708495 (Qualified 2026-09-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Broan AE110K = A000HFKTC with AE110KF ventilate safely?

Sizing outputs below convert Broan AE110K = A000HFKTC with AE110KF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AE110K = A000HFKTC with AE110KF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Broan AE110K = A000HFKTC with AE110KF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Amazon Basics B089R8S365**](https://siematic-charleston.com/ventilation-fans/amazon-basics-b089r8s365/) | 110 / 94.3 CFM | 1.0 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7107-03HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7107-03hw/) | 110 / 96 CFM | 1.0 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Milano TY-110-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-e/) | 110 / 94.5 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Milano TY-110-ESHL**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-eshl/) | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Milano TY-110-ESL**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-esl/) | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## Will Broan AE110K = A000HFKTC with AE110KF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AE110K = A000HFKTC with AE110KF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan AE110K = A000HFKTC with AE110KF in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan AE110K = A000HFKTC with AE110KF for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Broan AE110K = A000HFKTC with AE110KF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE110K = A000HFKTC with AE110KF.

### Does Broan AE110K = A000HFKTC with AE110KF satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan AE110K = A000HFKTC with AE110KF clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Broan AE110K = A000HFKTC with AE110KF undersized or poorly matched for a bath renovation?

Skip Broan AE110K = A000HFKTC with AE110KF if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Broan AE110K = A000HFKTC with AE110KF CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan AE110K = A000HFKTC with AE110KF registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Broan AE110K = A000HFKTC with AE110KF sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, Broan AE110K = A000HFKTC with AE110KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan AE110K = A000HFKTC with AE110KF?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan AE110K = A000HFKTC with AE110KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE110K = A000HFKTC with AE110KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE110K = A000HFKTC with AE110KF?

Broan AE110K = A000HFKTC with AE110KF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE110K = A000HFKTC with AE110KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE110K = A000HFKTC with AE110KF's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to Broan AE110K = A000HFKTC with AE110KF?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Broan AE110K = A000HFKTC with AE110KF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE110K = A000HFNF with AE110KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae110k-a000hfnf-with-ae110kf/)
- [Broan AE110L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae110l/)
- [Broan AE110K = A000HFKT with AE110KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae110k-a000hfkt-with-ae110kf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)