---
title: "Broan AE50=A000HFKTwithAE50F1 Bath Fan (50 CFM, 0.5 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfktwithae50f1/
description: "ENERGY STAR specs for Broan AE50=A000HFKTwithAE50F1: 50 CFM, 0.5 sones (#83 of 607), 3.5 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan AE50=A000HFKTwithAE50F1 Exhaust Fan Specifications

ENERGY STAR PD #2334575 · Bathroom/Utility Room · Qualified 2019-02-08

Verified Specification Summary

Homeowners specifying Broan AE50=A000HFKTwithAE50F1 gain 50 CFM at 0.1 in. w.g. (51.9 CFM at 0.25 in. w.g.) where it registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, venting bathrooms up to 51 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50=A000HFKTwithAE50F1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 51.9 CFM

- **Noise @ 0.1"**: 0.5 sones (#83/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 103.8% @ 0.25"

- **Motor Draw**: 14.3 W (5.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE50=A000HFKTwithAE50F1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, AE50=A000HFKTwithAE50F1 (series: FLEX) carries PD #2334575 dating to 2019-02-08. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).

## What acoustic percentile does Broan AE50=A000HFKTwithAE50F1 occupy among 1,145 bath blowers?

Inspect how Broan AE50=A000HFKTwithAE50F1 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Broan AE50=A000HFKTwithAE50F1 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AE50=A000HFKTwithAE50F1 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Broan AE50=A000HFKTwithAE50F1 acoustic and static metrics stand?

Compare Broan AE50=A000HFKTwithAE50F1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE50=A000HFKTwithAE50F1 / FLEX | PD ID 2334575 (Qualified 2019-02-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Broan AE50=A000HFKTwithAE50F1 handle taller ceilings or walk-in tub steam?

Evaluate how Broan AE50=A000HFKTwithAE50F1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AE50=A000HFKTwithAE50F1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 125.3 kWh/yr (~$20.05/yr) | 14.3 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Broan AE50=A000HFKTwithAE50F1?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK50S**](https://siematic-charleston.com/ventilation-fans/air-king-ak50s/) | 50 / 41.1 CFM | 0.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Air King FR50**](https://siematic-charleston.com/ventilation-fans/air-king-fr50/) | 50 / 42 CFM | 0.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Ortech ODE-5004**](https://siematic-charleston.com/ventilation-fans/ortech-ode-5004/) | 50 / 43.6 CFM | 0.4 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**ACIQ AP50**](https://siematic-charleston.com/ventilation-fans/aciq-ap50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| [**ACIQ ANP50**](https://siematic-charleston.com/ventilation-fans/aciq-anp50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |

## Is Broan AE50=A000HFKTwithAE50F1 sized right for your shower or tub room?

Check whether Broan AE50=A000HFKTwithAE50F1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan AE50=A000HFKTwithAE50F1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE50=A000HFKTwithAE50F1 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 51.9 CFM net static output
- **Works well for:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Broan AE50=A000HFKTwithAE50F1?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE50=A000HFKTwithAE50F1.

### Will long attic ducting choke Broan AE50=A000HFKTwithAE50F1 capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE50=A000HFKTwithAE50F1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Broan AE50=A000HFKTwithAE50F1 compared with a standard 3.0 sone builder fan?

Tested at 0.5 sones, Broan AE50=A000HFKTwithAE50F1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Broan AE50=A000HFKTwithAE50F1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE50=A000HFKTwithAE50F1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan AE50=A000HFKTwithAE50F1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50=A000HFKTwithAE50F1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE50=A000HFKTwithAE50F1?

Broan AE50=A000HFKTwithAE50F1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE50=A000HFKTwithAE50F1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50=A000HFKTwithAE50F1's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Broan AE50=A000HFKTwithAE50F1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE50=A000HFKTwithAE50F1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Broan AE50=A000HFKTwithAE50F1?

Rule out Broan AE50=A000HFKTwithAE50F1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## How can you cross-check Broan AE50=A000HFKTwithAE50F1 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Broan AE50=A000HFKTwithAE50F1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE50=A000HFNFwithAE50F1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfnfwithae50f1/)
- [Broan AE50=A000HFwithAE50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfwithae50f/)
- [Broan AE50 = A000HFKTC WITH AE50F1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfktc-with-ae50f1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
