#  Broan AE50=HPIVFNwithAE50F Exhaust Fan Specifications

ENERGY STAR PD #2271830 · Bathroom/Utility Room · Qualified 2016-07-01

Verified Specification Summary

Certified by EPA ENERGY STAR, Broan AE50=HPIVFNwithAE50F delivers 50 CFM free-air (51.9 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 51 sq ft (8-ft height) or 46 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50=HPIVFNwithAE50F Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 51.9 CFM

- **Noise @ 0.1"**: 0.5 sones (#83/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 103.8% @ 0.25"

- **Motor Draw**: 14.3 W (5.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE50=HPIVFNwithAE50F vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU AE50=HPIVFNwithAE50F (series: InVent) (PD #2271830) certified since 2016-07-01. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).

## How noisy is Broan AE50=HPIVFNwithAE50F compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan AE50=HPIVFNwithAE50F measures 0.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Broan AE50=HPIVFNwithAE50F airflow?

Connecting Broan AE50=HPIVFNwithAE50F through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Broan AE50=HPIVFNwithAE50F performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan AE50=HPIVFNwithAE50F lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE50=HPIVFNwithAE50F / InVent | PD ID 2271830 (Qualified 2016-07-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Broan AE50=HPIVFNwithAE50F?

Calculated coverage metrics translate Broan AE50=HPIVFNwithAE50F airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan AE50=HPIVFNwithAE50F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 125.3 kWh/yr (~$20.05/yr) | 14.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Broan AE50=HPIVFNwithAE50F?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK50S**](https://siematic-charleston.com/ventilation-fans/air-king-ak50s/) | 50 / 41.1 CFM | 0.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Air King FR50**](https://siematic-charleston.com/ventilation-fans/air-king-fr50/) | 50 / 42 CFM | 0.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Ortech ODE-5004**](https://siematic-charleston.com/ventilation-fans/ortech-ode-5004/) | 50 / 43.6 CFM | 0.4 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**ACIQ AP50**](https://siematic-charleston.com/ventilation-fans/aciq-ap50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| [**ACIQ ANP50**](https://siematic-charleston.com/ventilation-fans/aciq-anp50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |

## Does Broan AE50=HPIVFNwithAE50F match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan AE50=HPIVFNwithAE50F percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan AE50=HPIVFNwithAE50F on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE50=HPIVFNwithAE50F carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 51.9 CFM net static output
- **Works well for:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Broan AE50=HPIVFNwithAE50F?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan AE50=HPIVFNwithAE50F.

### Will long attic ducting choke Broan AE50=HPIVFNwithAE50F capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE50=HPIVFNwithAE50F from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Broan AE50=HPIVFNwithAE50F compared with a standard 3.0 sone builder fan?

Tested at 0.5 sones, Broan AE50=HPIVFNwithAE50F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Broan AE50=HPIVFNwithAE50F consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE50=HPIVFNwithAE50F draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan AE50=HPIVFNwithAE50F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50=HPIVFNwithAE50F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE50=HPIVFNwithAE50F?

Broan AE50=HPIVFNwithAE50F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE50=HPIVFNwithAE50F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50=HPIVFNwithAE50F's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Broan AE50=HPIVFNwithAE50F score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE50=HPIVFNwithAE50F delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Broan AE50=HPIVFNwithAE50F?

Rule out Broan AE50=HPIVFNwithAE50F when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## Where can you explore more benchmarks around Broan AE50=HPIVFNwithAE50F?

Use the related reference pages and estimators below to cross-check Broan AE50=HPIVFNwithAE50F against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech ODC-9006 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odc-9006/)
- [ACIQ ANP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-anp80/)
- [Broan AE50=A000HFwithAE50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfwithae50f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)