title: "Broan AE50 Bath Fan (50 CFM, 0.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-ae50/
description: "ENERGY STAR specs for Broan AE50: 50 CFM, 0.5 sones (#83 of 607), 3.5 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Broan AE50 Exhaust Fan Specifications

ENERGY STAR PD #2248769 · Bathroom/Utility Room · Qualified 2015-09-01

Verified Specification Summary

Tested under HVI protocols, the Broan AE50 exhaust unit achieves 50 CFM at 0.1 in. w.g. (51.9 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, covering standard baths up to 51 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 51.9 CFM

- **Noise @ 0.1"**: 0.5 sones (#83/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 103.8% @ 0.25"

- **Motor Draw**: 14.3 W (5.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE50 (series: Invent) under PD #2248769 (207 models registered, 2015-09-01). Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).

## Where do Broan AE50 sones rank across EPA ENERGY STAR fans?

Comparing Broan AE50 (0.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Broan AE50 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE50, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan AE50 measure up on airflow and noise ratings?

Each row below breaks down Broan AE50 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE50 / Invent | PD ID 2248769 (Qualified 2015-09-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan AE50 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AE50

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 125.3 kWh/yr (~$20.05/yr) | 14.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan AE50?

Compare Broan AE50 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK50S**](https://siematic-charleston.com/ventilation-fans/air-king-ak50s/) | 50 / 41.1 CFM | 0.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Air King FR50**](https://siematic-charleston.com/ventilation-fans/air-king-fr50/) | 50 / 42 CFM | 0.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Ortech ODE-5004**](https://siematic-charleston.com/ventilation-fans/ortech-ode-5004/) | 50 / 43.6 CFM | 0.4 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**ACIQ AP50**](https://siematic-charleston.com/ventilation-fans/aciq-ap50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| [**ACIQ ANP50**](https://siematic-charleston.com/ventilation-fans/aciq-anp50/) | 50 / 42.3 CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |

## Can you size Broan AE50 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE50 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Broan AE50?

Match Broan AE50 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 51.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 0.5 sones up to 51 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Broan AE50?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE50.

### Where does Broan AE50 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AE50.

### What happens to Broan AE50 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan AE50 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Broan AE50 sit on acoustic comfort for senior homeowners?

Measuring 0.5 sones, Broan AE50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Broan AE50 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan AE50 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Broan AE50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE50?

Broan AE50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Broan AE50 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AE50 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## What neighboring pages and tools support Broan AE50?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan AE50.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE50=A000HF2WITHAE50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hf2withae50f/)
- [Broan AE50 = A000HFKTC WITH AE50F1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-a000hfktc-with-ae50f1/)
- [Air King AK50S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak50s/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)