title: "Broan AE50110DC = A000HFKTC WITH AE50110DCF Bath Fan (110 CFM)"
url: https://siematic-charleston.com/ventilation-fans/broan-ae50110dc-a000hfktc-with-ae50110dcf/
description: "ENERGY STAR specs for Broan AE50110DC = A000HFKTC WITH AE50110DCF: 110 CFM, 9.6 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan AE50110DC = A000HFKTC WITH AE50110DCF Exhaust Fan Specifications

ENERGY STAR PD #4191422 · Bathroom/Utility Room · Qualified 2025-05-23

Verified Specification Summary

The Broan AE50110DC = A000HFKTC WITH AE50110DCF (FLEX SERIES) moves 110 CFM at 0.1 in. w.g. (112.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.6 CFM/W efficacy, sizing bathrooms up to 112 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50110DC = A000HFKTC WITH AE50110DCF Exhaust before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 112.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.6 CFM/W (#206/1,145)

- **Static Retention**: 101.9% @ 0.25"

- **Motor Draw**: 11.5 W (4.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE50110DC = A000HFKTC WITH AE50110DCF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AE50110DC = A000HFKTC WITH AE50110DCF (EPA filing PD #4191422) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.1 CFM out of 110 CFM (101.9% retention, 14.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE50110DC = A000HFKTC WITH AE50110DCF (series: FLEX SERIES) under PD #4191422 (207 models registered, 2025-05-23). Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How does duct geometry alter Broan AE50110DC = A000HFKTC WITH AE50110DCF static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE50110DC = A000HFKTC WITH AE50110DCF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE50110DC = A000HFKTC WITH AE50110DCF / FLEX SERIES | PD ID 4191422 (Qualified 2025-05-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Broan AE50110DC = A000HFKTC WITH AE50110DCF ventilate safely?

Sizing outputs below convert Broan AE50110DC = A000HFKTC WITH AE50110DCF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AE50110DC = A000HFKTC WITH AE50110DCF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 100.7 kWh/yr (~$16.11/yr) | 11.5 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Broan AE50110DC = A000HFKTC WITH AE50110DCF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Will Broan AE50110DC = A000HFKTC WITH AE50110DCF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AE50110DC = A000HFKTC WITH AE50110DCF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan AE50110DC = A000HFKTC WITH AE50110DC fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE50110DC = A000HFKTC WITH AE50110DC.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 112 sq ft with 8-ft ceilings (99 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE50110DC = A000HFKTC WITH AE50110DCF.

### Will Broan AE50110DC = A000HFKTC WITH AE50110DCF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan AE50110DC = A000HFKTC WITH AE50110DCF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Broan AE50110DC = A000HFKTC WITH AE50110DCF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan AE50110DC = A000HFKTC WITH AE50110DCF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan AE50110DC = A000HFKTC WITH AE50110DCF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50110DC = A000HFKTC WITH AE50110DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Broan AE50110DC = A000HFKTC WITH AE50110DCF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE50110DC = A000HFKTC WITH AE50110DCF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50110DC = A000HFKTC WITH AE50110DCF's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan AE50110DC = A000HFKTC WITH AE50110DCF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE50110DC = A000HFKTC WITH AE50110DCF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Do not force Broan AE50110DC = A000HFKTC WITH AE50110DCF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan AE50110DC = A000HFKTC WITH AE50110DCF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan AE50110DC = A000HFKTC WITH AE50110DCF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Which guides and calculators connect next to Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Broan AE50110DC = A000HFKTC WITH AE50110DCF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE50110DC = A000HFNF with AE50110DCF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50110dc-a000hfnf-with-ae50110dcf/)
- [Broan AE50110DCL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50110dcl/)
- [Broan AE50110DC = A000HFKT with AE50110DCF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50110dc-a000hfkt-with-ae50110dcf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications