#  Broan AE80BL=H000HLKT with AE80BLF1 Exhaust Fan Specifications

ENERGY STAR PD #2524258 · Bathroom/Utility Room · Qualified 2023-06-23

Verified Specification Summary

Homeowners specifying Broan AE80BL=H000HLKT with AE80BLF1 gain 80 CFM at 0.1 in. w.g. (60 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 3.0 CFM/W efficacy, venting bathrooms up to 60 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80BL=H000HLKT with AE80BLF1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 60 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 3.0 CFM/W (#1,105/1,145)

- **Static Retention**: 75.0% @ 0.25"

- **Motor Draw**: 26.7 W (9.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE80BL=H000HLKT with AE80BLF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, AE80BL=H000HLKT with AE80BLF1 (series: FLEX) carries PD #2524258 dating to 2023-06-23. Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.7 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 233.9 kWh/yr (~$37.42/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).

## What acoustic percentile does Broan AE80BL=H000HLKT with AE80BLF1 occupy among 1,145 bath blowers?

Inspect how Broan AE80BL=H000HLKT with AE80BLF1 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Broan AE80BL=H000HLKT with AE80BLF1 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AE80BL=H000HLKT with AE80BLF1 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Broan AE80BL=H000HLKT with AE80BLF1 acoustic and static metrics stand?

Compare Broan AE80BL=H000HLKT with AE80BLF1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE80BL=H000HLKT with AE80BLF1 / FLEX | PD ID 2524258 (Qualified 2023-06-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Can Broan AE80BL=H000HLKT with AE80BLF1 handle taller ceilings or walk-in tub steam?

Evaluate how Broan AE80BL=H000HLKT with AE80BLF1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AE80BL=H000HLKT with AE80BLF1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 233.9 kWh/yr (~$37.42/yr) | 26.7 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Broan AE80BL=H000HLKT with AE80BLF1?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Milano TY-80-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-80-e/) | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Milano TY-80-EH**](https://siematic-charleston.com/ventilation-fans/milano-ty-80-eh/) | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Hunter 90704**](https://siematic-charleston.com/ventilation-fans/hunter-90704/) | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Hunter 90705**](https://siematic-charleston.com/ventilation-fans/hunter-90705/) | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Nutone AER80LWH**](https://siematic-charleston.com/ventilation-fans/nutone-aer80lwh/) | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |

## Is Broan AE80BL=H000HLKT with AE80BLF1 sized right for your shower or tub room?

Check whether Broan AE80BL=H000HLKT with AE80BLF1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Broan AE80BL=H000HLKT with AE80BLF1?

Compare where Broan AE80BL=H000HLKT with AE80BLF1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 60 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Broan AE80BL=H000HLKT with AE80BLF1?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE80BL=H000HLKT with AE80BLF1.

### Why might a contractor swap Broan AE80BL=H000HLKT with AE80BLF1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80BL=H000HLKT with AE80BLF1 lacks adequate reserve.

### How does Broan AE80BL=H000HLKT with AE80BLF1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80BL=H000HLKT with AE80BLF1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Broan AE80BL=H000HLKT with AE80BLF1 quiet enough for a primary bedroom bathroom?

At 0.7 sones, Broan AE80BL=H000HLKT with AE80BLF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Broan AE80BL=H000HLKT with AE80BLF1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Broan AE80BL=H000HLKT with AE80BLF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80BL=H000HLKT with AE80BLF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE80BL=H000HLKT with AE80BLF1?

Broan AE80BL=H000HLKT with AE80BLF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE80BL=H000HLKT with AE80BLF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80BL=H000HLKT with AE80BLF1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Broan AE80BL=H000HLKT with AE80BLF1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE80BL=H000HLKT with AE80BLF1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## How can you cross-check Broan AE80BL=H000HLKT with AE80BLF1 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Broan AE80BL=H000HLKT with AE80BLF1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE80BL=H000HLNF with AE80BLF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80bl-h000hlnf-with-ae80blf1/)
- [Broan AE80BLR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80blr/)
- [Broan AE80BL=A000HLNF with AE80BLF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80bl-a000hlnf-with-ae80blf1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)