title: "Broan AE80BL=H000HLNF with AE80BLF1 Bath Fan (80 CFM, 0.7 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-ae80bl-h000hlnf-with-ae80blf1/
description: "ENERGY STAR specs for Broan AE80BL=H000HLNF with AE80BLF1: 80 CFM, 0.7 sones (#135 of 607), 3.0 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan AE80BL=H000HLNF with AE80BLF1 Exhaust Fan Specifications

ENERGY STAR PD #2524259 · Bathroom/Utility Room · Qualified 2023-06-23

Verified Specification Summary

Rated for 80 CFM open-air (60 CFM at 0.25 in. w.g.), Broan AE80BL=H000HLNF with AE80BLF1 registers #135 of 607 in quietness (0.7 sones) and delivers 3.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80BL=H000HLNF with AE80BLF1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 60 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 3.0 CFM/W (#1,105/1,145)

- **Static Retention**: 75.0% @ 0.25"

- **Motor Draw**: 26.7 W (9.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE80BL=H000HLNF with AE80BLF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2524259 verifies AE80BL=H000HLNF with AE80BLF1 (series: FLEX) under Broan (207 listed models, qualified 2023-06-23). Lighting kit: Yes. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.7 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 233.9 kWh/yr (~$37.42/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).

## How does Broan AE80BL=H000HLNF with AE80BLF1 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80BL=H000HLNF with AE80BLF1 (0.7 sones).

## How do flex elbows choke Broan AE80BL=H000HLNF with AE80BLF1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan AE80BL=H000HLNF with AE80BLF1 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan AE80BL=H000HLNF with AE80BLF1 meet residential exhaust fan code specs?

Inspect Broan AE80BL=H000HLNF with AE80BLF1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE80BL=H000HLNF with AE80BLF1 / FLEX | PD ID 2524259 (Qualified 2023-06-23) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Broan AE80BL=H000HLNF with AE80BLF1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan AE80BL=H000HLNF with AE80BLF1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan AE80BL=H000HLNF with AE80BLF1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 233.9 kWh/yr (~$37.42/yr) | 26.7 W x 8,760 hrs / 1,000 |

## Which competing models share Broan AE80BL=H000HLNF with AE80BLF1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Milano TY-80-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-80-e/) | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Milano TY-80-EH**](https://siematic-charleston.com/ventilation-fans/milano-ty-80-eh/) | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Hunter 90704**](https://siematic-charleston.com/ventilation-fans/hunter-90704/) | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Hunter 90705**](https://siematic-charleston.com/ventilation-fans/hunter-90705/) | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Nutone AER80LWH**](https://siematic-charleston.com/ventilation-fans/nutone-aer80lwh/) | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |

## How much airflow margin does Broan AE80BL=H000HLNF with AE80BLF1 give your bath?

Run a quick local room-volume check for Broan AE80BL=H000HLNF with AE80BLF1 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Broan AE80BL=H000HLNF with AE80BLF1?

Match Broan AE80BL=H000HLNF with AE80BLF1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Broan AE80BL=H000HLNF with AE80BLF1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80BL=H000HLNF with AE80BLF1.

### What does Broan AE80BL=H000HLNF with AE80BLF1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan AE80BL=H000HLNF with AE80BLF1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Broan AE80BL=H000HLNF with AE80BLF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80BL=H000HLNF with AE80BLF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE80BL=H000HLNF with AE80BLF1?

Broan AE80BL=H000HLNF with AE80BLF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE80BL=H000HLNF with AE80BLF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80BL=H000HLNF with AE80BLF1's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Broan AE80BL=H000HLNF with AE80BLF1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AE80BL=H000HLNF with AE80BLF1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Broan AE80BL=H000HLNF with AE80BLF1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AE80BL=H000HLNF with AE80BLF1.

### What happens to Broan AE80BL=H000HLNF with AE80BLF1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan AE80BL=H000HLNF with AE80BLF1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Broan AE80BL=H000HLNF with AE80BLF1 sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, Broan AE80BL=H000HLNF with AE80BLF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## Which GradeMark tools pair best with Broan AE80BL=H000HLNF with AE80BLF1?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan AE80BL=H000HLNF with AE80BLF1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE80BLR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80blr/)
- [Broan AE80BR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80br/)
- [Broan AE80BL=H000HLKT with AE80BLF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80bl-h000hlkt-with-ae80blf1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)