title: "Broan AE80K = A000HFKT with AE80KF Bath Fan (80 CFM, 0.6 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfkt-with-ae80kf/
description: "ENERGY STAR specs for Broan AE80K = A000HFKT with AE80KF: 80 CFM, 0.6 sones (#107 of 607), 3.9 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Broan AE80K = A000HFKT with AE80KF Exhaust Fan Specifications

ENERGY STAR PD #4697774 · Bathroom/Utility Room · Qualified 2026-09-02

Verified Specification Summary

Rated for 80 CFM open-air (74.5 CFM at 0.25 in. w.g.), Broan AE80K = A000HFKT with AE80KF registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 74 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K = A000HFKT with AE80KF Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 74.5 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 93.1% @ 0.25"

- **Motor Draw**: 20.5 W (7.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE80K = A000HFKT with AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan's 207-unit lineup, AE80K = A000HFKT with AE80KF (series: INVENT) carries PD #4697774 dating to 2026-09-02. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).

## How does Broan AE80K = A000HFKT with AE80KF acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80K = A000HFKT with AE80KF (0.6 sones).

## How do flex elbows choke Broan AE80K = A000HFKT with AE80KF at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan AE80K = A000HFKT with AE80KF moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan AE80K = A000HFKT with AE80KF meet residential exhaust fan code specs?

Inspect Broan AE80K = A000HFKT with AE80KF mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE80K = A000HFKT with AE80KF / INVENT | PD ID 4697774 (Qualified 2026-09-02) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (74.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Broan AE80K = A000HFKT with AE80KF airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan AE80K = A000HFKT with AE80KF tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan AE80K = A000HFKT with AE80KF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 74 sq ft | 1 CFM/sq ft @ 74.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 24 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |

## Which competing models share Broan AE80K = A000HFKT with AE80KF airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hunter 90704**](https://siematic-charleston.com/ventilation-fans/hunter-90704/) | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**Hunter 90705**](https://siematic-charleston.com/ventilation-fans/hunter-90705/) | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5OR**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SG**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sg/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SN**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sn/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |

## How much airflow margin does Broan AE80K = A000HFKT with AE80KF give your bath?

Run a quick local room-volume check for Broan AE80K = A000HFKT with AE80KF by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Broan AE80K = A000HFKT with AE80KF?

Compare where Broan AE80K = A000HFKT with AE80KF excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 24 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 74 sq ft with 8-ft ceilings (66 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Broan AE80K = A000HFKT with AE80KF?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80K = A000HFKT with AE80KF.

### Why might a contractor swap Broan AE80K = A000HFKT with AE80KF for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80K = A000HFKT with AE80KF lacks adequate reserve.

### How does Broan AE80K = A000HFKT with AE80KF handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80K = A000HFKT with AE80KF yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Broan AE80K = A000HFKT with AE80KF quiet enough for a primary bedroom bathroom?

At 0.6 sones, Broan AE80K = A000HFKT with AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Broan AE80K = A000HFKT with AE80KF energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Broan AE80K = A000HFKT with AE80KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K = A000HFKT with AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE80K = A000HFKT with AE80KF?

Broan AE80K = A000HFKT with AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE80K = A000HFKT with AE80KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K = A000HFKT with AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Broan AE80K = A000HFKT with AE80KF serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE80K = A000HFKT with AE80KF supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## Which GradeMark tools pair best with Broan AE80K = A000HFKT with AE80KF?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan AE80K = A000HFKT with AE80KF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE80K = A000HFKTC WITH AE80KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfktc-with-ae80kf/)
- [Broan AE80K = A000HFNF with AE80KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfnf-with-ae80kf/)
- [Broan AE80K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80k-2369230/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)