title: "Broan AE80K = A000HFKTC WITH AE80KF Bath Fan (80 CFM, 0.6 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfktc-with-ae80kf/
description: "ENERGY STAR specs for Broan AE80K = A000HFKTC WITH AE80KF: 80 CFM, 0.6 sones (#107 of 607), 3.9 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Broan AE80K = A000HFKTC WITH AE80KF Exhaust Fan Specifications

ENERGY STAR PD #3999568 · Bathroom/Utility Room · Qualified 2025-03-07

Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan AE80K = A000HFKTC WITH AE80KF tests at 80 CFM free discharge (74.5 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 74 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K = A000HFKTC WITH AE80KF Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 74.5 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 93.1% @ 0.25"

- **Motor Draw**: 20.5 W (7.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AE80K = A000HFKTC WITH AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #3999568 verifies AE80K = A000HFKTC WITH AE80KF (series: FLEX SERIES) under Broan (207 listed models, qualified 2025-03-07). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).

## Does Broan AE80K = A000HFKTC WITH AE80KF fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan AE80K = A000HFKTC WITH AE80KF at 0.6 sones.

## Why avoid unvented attic termination with Broan AE80K = A000HFKTC WITH AE80KF?

Under ASHRAE 62.2 best practice, Broan AE80K = A000HFKTC WITH AE80KF needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Broan AE80K = A000HFKTC WITH AE80KF?

Before cutting ceiling drywall or sizing attic transitions for Broan AE80K = A000HFKTC WITH AE80KF, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AE80K = A000HFKTC WITH AE80KF / FLEX SERIES | PD ID 3999568 (Qualified 2025-03-07) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (74.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Broan AE80K = A000HFKTC WITH AE80KF?

Bathroom ventilation sizing below maps Broan AE80K = A000HFKTC WITH AE80KF motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan AE80K = A000HFKTC WITH AE80KF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 74 sq ft | 1 CFM/sq ft @ 74.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 24 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Broan AE80K = A000HFKTC WITH AE80KF in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan AE80K = A000HFKTC WITH AE80KF.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hunter 90704**](https://siematic-charleston.com/ventilation-fans/hunter-90704/) | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**Hunter 90705**](https://siematic-charleston.com/ventilation-fans/hunter-90705/) | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5OR**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SG**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sg/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80L5SN**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5sn/) | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |

## What percentage of room demand does Broan AE80K = A000HFKTC WITH AE80KF cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan AE80K = A000HFKTC WITH AE80KF tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan AE80K = A000HFKTC WITH AE80KF on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE80K = A000HFKTC WITH AE80KF carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 74.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 0.6 sones up to 74 sq ft
- **Works well for:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Broan AE80K = A000HFKTC WITH AE80KF?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan AE80K = A000HFKTC WITH AE80KF.

### What duct and room conditions disqualify Broan AE80K = A000HFKTC WITH AE80KF?

Rule out Broan AE80K = A000HFKTC WITH AE80KF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Broan AE80K = A000HFKTC WITH AE80KF capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE80K = A000HFKTC WITH AE80KF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Broan AE80K = A000HFKTC WITH AE80KF compared with a standard 3.0 sone builder fan?

Tested at 0.6 sones, Broan AE80K = A000HFKTC WITH AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Broan AE80K = A000HFKTC WITH AE80KF consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE80K = A000HFKTC WITH AE80KF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan AE80K = A000HFKTC WITH AE80KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K = A000HFKTC WITH AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AE80K = A000HFKTC WITH AE80KF?

Broan AE80K = A000HFKTC WITH AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AE80K = A000HFKTC WITH AE80KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K = A000HFKTC WITH AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Broan AE80K = A000HFKTC WITH AE80KF score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE80K = A000HFKTC WITH AE80KF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## What related resources expand on Broan AE80K = A000HFKTC WITH AE80KF?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AE80K = A000HFNF with AE80KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfnf-with-ae80kf/)
- [Broan AE80S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80s-2369232/)
- [Broan AE80K = A000HFKT with AE80KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfkt-with-ae80kf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)