---
title: "Broan AEW110 Bath Fan (110 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-aew110/
description: "ENERGY STAR specs for Broan AEW110: 110 CFM, 1.0 sones (#265 of 607), 4.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Broan AEW110 Exhaust Fan Specifications

ENERGY STAR PD #4697414 · Bathroom/Utility Room · Qualified 2026-08-19

Verified Specification Summary

The Broan AEW110 (INVENT) moves 110 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AEW110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 95.5 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 86.8% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan AEW110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4697414 verifies AEW110 (series: INVENT) under Broan (207 listed models, qualified 2026-08-19). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).

## Where does Broan AEW110 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Broan AEW110 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Broan AEW110?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AEW110 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AEW110 / INVENT | PD ID 4697414 (Qualified 2026-08-19) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Broan AEW110 ventilate safely?

Sizing outputs below convert Broan AEW110 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AEW110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Broan AEW110 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Amazon Basics B089R8S365**](https://siematic-charleston.com/ventilation-fans/amazon-basics-b089r8s365/) | 110 / 94.3 CFM | 1.0 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7107-03HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7107-03hw/) | 110 / 96 CFM | 1.0 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Milano TY-110-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-e/) | 110 / 94.5 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Milano TY-110-ESHL**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-eshl/) | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Milano TY-110-ESL**](https://siematic-charleston.com/ventilation-fans/milano-ty-110-esl/) | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## Will Broan AEW110 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AEW110 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan AEW110 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AEW110.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Broan AEW110?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AEW110.

### Will Broan AEW110 disturb adjacent bedrooms during night use?

Acoustic measurement places Broan AEW110 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Broan AEW110 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan AEW110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan AEW110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AEW110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan AEW110?

Broan AEW110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan AEW110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AEW110's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan AEW110 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AEW110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan AEW110?

Do not force Broan AEW110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan AEW110 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan AEW110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Which guides and calculators connect next to Broan AEW110?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Broan AEW110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta 110F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-110f/)
- [Delta VFB25ADBT Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-vfb25adbt/)
- [Broan AER110S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-aer110s/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
