#  Broan FIN-180B-HW Exhaust Fan Specifications

ENERGY STAR PD #2401613 · In-line (single-port) · Qualified 2022-09-16

Verified Specification Summary

Certified by EPA ENERGY STAR, Broan FIN-180B-HW delivers 180 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 6.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 180 sq ft (8-ft height) or 160 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan FIN-180B-HW Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 180 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.8 CFM/W (#429/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 26.5 W (9.7 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan FIN-180B-HW vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan FIN-180B-HW (EPA filing PD #2401613) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2401613 verifies FIN-180B-HW (series: FIN-180) under Broan (207 listed models, qualified 2022-09-16). Lighting kit: No. At 6.8 CFM/W (#429 of 1,145, top 37.6% of 1,145 rated models, more efficient than 62.4% of rated models, 2.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.5 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 232.1 kWh/yr (~$37.14/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Ortech OIF5-190 (180.0 CFM).

## Why does rigid 6 in. diameter ducting protect Broan FIN-180B-HW airflow?

Connecting Broan FIN-180B-HW through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Broan FIN-180B-HW performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan FIN-180B-HW lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FIN-180B-HW / FIN-180 | PD ID 2401613 (Qualified 2022-09-16) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (180 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Broan FIN-180B-HW?

Calculated coverage metrics translate Broan FIN-180B-HW airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan FIN-180B-HW

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 180 sq ft | 1 CFM/sq ft @ 180 CFM |
| Tall Bath (9-ft Ceiling) | Up to 160 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 130 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 232.1 kWh/yr (~$37.14/yr) | 26.5 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Broan FIN-180B-HW?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| [**Ortech OIF5-190**](https://siematic-charleston.com/ventilation-fans/ortech-oif5-190/) | 180 / N/A CFM | Unpublished | 4.9 CFM/W | 5 in. diameter |
| [**S&P RF10-160EC**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| [**S&P RF10-160EC-ES24V**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec-es24v/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| [**S&P RF10-160EC-P**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec-p/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |

## Does Broan FIN-180B-HW match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan FIN-180B-HW percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Broan FIN-180B-HW?

Compare where Broan FIN-180B-HW excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 130 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 180 CFM net static output
- **Suited to:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Broan FIN-180B-HW?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan FIN-180B-HW.

### How does Broan FIN-180B-HW handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan FIN-180B-HW yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Broan FIN-180B-HW quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Broan FIN-180B-HW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Broan FIN-180B-HW energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Broan FIN-180B-HW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan FIN-180B-HW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan FIN-180B-HW?

Broan FIN-180B-HW features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan FIN-180B-HW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan FIN-180B-HW's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Broan FIN-180B-HW serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan FIN-180B-HW supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Broan FIN-180B-HW for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan FIN-180B-HW lacks adequate reserve.

## Where can you explore more benchmarks around Broan FIN-180B-HW?

Use the related reference pages and estimators below to cross-check Broan FIN-180B-HW against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-15NLFS1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-15nlfs1/)
- [Panasonic FV-15NLFS1H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-15nlfs1h/)
- [Broan FIN-180B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)