#  Broan FIN-180P Exhaust Fan Specifications

ENERGY STAR PD #2343239 · In-line (single-port) · Qualified 2018-09-28

Verified Specification Summary

Tested under HVI protocols, the Broan FIN-180P exhaust unit achieves 180 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 6.4 CFM/W efficacy, covering standard baths up to 180 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan FIN-180P Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 180 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.4 CFM/W (#438/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 28.1 W (10.3 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan FIN-180P vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan FIN-180P (EPA filing PD #2343239) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Broan FIN-180P (series: FIN180P) under PD #2343239 (207 models registered, 2018-09-28). Lighting kit: No. At 6.4 CFM/W (#438 of 1,145, top 38.8% of 1,145 rated models, more efficient than 61.2% of rated models, 1.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 28.1 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 246.2 kWh/yr (~$39.39/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Ortech OIF5-190 (180.0 CFM).

## What attic duct routing preserves Broan FIN-180P CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan FIN-180P, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan FIN-180P measure up on airflow and noise ratings?

Each row below breaks down Broan FIN-180P certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FIN-180P / FIN180P | PD ID 2343239 (Qualified 2018-09-28) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (180 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan FIN-180P CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan FIN-180P

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 180 sq ft | 1 CFM/sq ft @ 180 CFM |
| Tall Bath (9-ft Ceiling) | Up to 160 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 130 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 246.2 kWh/yr (~$39.39/yr) | 28.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan FIN-180P?

Compare Broan FIN-180P side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| [**Ortech OIF5-190**](https://siematic-charleston.com/ventilation-fans/ortech-oif5-190/) | 180 / N/A CFM | Unpublished | 4.9 CFM/W | 5 in. diameter |
| [**S&P RF10-160EC**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| [**S&P RF10-160EC-ES24V**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec-es24v/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| [**S&P RF10-160EC-P**](https://siematic-charleston.com/ventilation-fans/s-p-rf10-160ec-p/) | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |

## Can you size Broan FIN-180P for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan FIN-180P verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan FIN-180P fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan FIN-180P.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 180 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 180 sq ft
- **Target scenario:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Broan FIN-180P?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan FIN-180P.

### Does running Broan FIN-180P continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan FIN-180P draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan FIN-180P pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan FIN-180P's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan FIN-180P?

Broan FIN-180P features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan FIN-180P's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan FIN-180P's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan FIN-180P code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan FIN-180P clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan FIN-180P?

Do not force Broan FIN-180P into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan FIN-180P retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan FIN-180P produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will Broan FIN-180P disturb adjacent bedrooms during night use?

Acoustic measurement places Broan FIN-180P at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## What neighboring pages and tools support Broan FIN-180P?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan FIN-180P.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan FIN-180P-HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-fin-180p-hw/)
- [Ortech OIF5-190 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oif5-190/)
- [Broan ALT4306SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss-4481124/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)