---
title: "Broan GLA1303BL Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-gla1303bl/
description: "ENERGY STAR specs for Broan GLA1303BL: 150 CFM, 4.6 CFM/W, 7 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Broan GLA1303BL Exhaust Fan Specifications

ENERGY STAR PD #3629809 · Range Hood · Qualified 2024-09-13

Verified Specification Summary

The Broan GLA1303BL (RANGE HOOD) moves 150 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.6 CFM/W efficacy, sizing bathrooms up to 150 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan GLA1303BL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 32.6 W (11.9 kWh/yr)

- **Duct & Tier**: 7 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan GLA1303BL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan GLA1303BL (EPA filing PD #3629809) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, GLA1303BL (series: RANGE HOOD) carries PD #3629809 dating to 2024-09-13. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

## How does duct geometry alter Broan GLA1303BL static pressure?

Smooth 7 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Broan GLA1303BL?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan GLA1303BL alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | GLA1303BL / RANGE HOOD | PD ID 3629809 (Qualified 2024-09-13) |
| **Duct Connection** | 7 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Broan GLA1303BL ventilate safely?

Sizing outputs below convert Broan GLA1303BL tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan GLA1303BL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Broan GLA1303BL closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |

## Will Broan GLA1303BL clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan GLA1303BL satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan GLA1303BL fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan GLA1303BL.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 100 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 150 sq ft with 8-ft ceilings (133 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 7 in. diameter

## What key rules and numbers govern Broan GLA1303BL?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan GLA1303BL.

### How much airflow does Broan GLA1303BL retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan GLA1303BL produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 7 in. diameter metal duct transitions.

### Will Broan GLA1303BL disturb adjacent bedrooms during night use?

Acoustic measurement places Broan GLA1303BL at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Broan GLA1303BL continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan GLA1303BL draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan GLA1303BL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan GLA1303BL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan GLA1303BL?

Broan GLA1303BL features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan GLA1303BL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan GLA1303BL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan GLA1303BL code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan GLA1303BL clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan GLA1303BL?

Do not force Broan GLA1303BL into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## Which guides and calculators connect next to Broan GLA1303BL?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Broan GLA1303BL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan GLA1303SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-gla1303ss/)
- [Broan GLA1303WW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-gla1303ww/)
- [Broan GLA1243WW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-gla1243ww/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
