---
title: "Broan GLA3304WW Bath Fan (160 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-gla3304ww/
description: "ENERGY STAR specs for Broan GLA3304WW: 160 CFM, 3.8 CFM/W, 3.25 x 10 in. rectangular and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Broan GLA3304WW Exhaust Fan Specifications

ENERGY STAR PD #3998908 · Range Hood · Qualified 2025-02-21

Verified Specification Summary

Rated for 160 CFM open-air (unpublished 0.25 in. w.g. output), Broan GLA3304WW omits a published 0.1-inch sone rating and delivers 3.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 160 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan GLA3304WW Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 160 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 42.1 W (15.4 kWh/yr)

- **Duct & Tier**: 3.25 x 10 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan GLA3304WW vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan GLA3304WW (EPA filing PD #3998908) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.

Certification audit confirms Broan GLA3304WW (series: RANGE HOOD) under PD #3998908 (207 models registered, 2025-02-21). Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 42.1 watts, about 15.4 kWh/yr (~$2.46/yr at $0.16/kWh) for 1 hr/day shower timers or 368.8 kWh/yr (~$59.01/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan ALT4306SS (160.0 CFM).

## How do flex elbows choke Broan GLA3304WW at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3.25 x 10 in. rectangular metal pipe keeps Broan GLA3304WW moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan GLA3304WW meet residential exhaust fan code specs?

Inspect Broan GLA3304WW mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | GLA3304WW / RANGE HOOD | PD ID 3998908 (Qualified 2025-02-21) |
| **Duct Connection** | 3.25 x 10 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Broan GLA3304WW airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan GLA3304WW tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan GLA3304WW

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.4 kWh/yr (~$2.46/yr) | 42.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 368.8 kWh/yr (~$59.01/yr) | 42.1 W x 8,760 hrs / 1,000 |

## Which competing models share Broan GLA3304WW airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Best UCB3I30BLSB**](https://siematic-charleston.com/ventilation-fans/best-ucb3i30blsb/) | 160 / N/A CFM | Unpublished | 3.2 CFM/W | 3.25 in. diameter |

## How much airflow margin does Broan GLA3304WW give your bath?

Run a quick local room-volume check for Broan GLA3304WW by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan GLA3304WW on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan GLA3304WW carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 3.25 x 10 in. rectangular

## What should homeowners verify first about Broan GLA3304WW?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan GLA3304WW.

### How much power does Broan GLA3304WW consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan GLA3304WW draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan GLA3304WW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan GLA3304WW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan GLA3304WW?

Broan GLA3304WW features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan GLA3304WW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan GLA3304WW's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Broan GLA3304WW score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan GLA3304WW delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Broan GLA3304WW?

Rule out Broan GLA3304WW when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Broan GLA3304WW capacity?

Because static drag at 0.25 in. w.g. lowers Broan GLA3304WW from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3.25 x 10 in. rectangular rigid ducting straight to a dedicated exterior damper.

### How loud is Broan GLA3304WW compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Broan GLA3304WW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

## Which GradeMark tools pair best with Broan GLA3304WW?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan GLA3304WW.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan GLA3364SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-gla3364ss/)
- [Broan MTR3304SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr3304ss/)
- [Broan GLA3304SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-gla3304ss/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
