title: "Broan L200EL Bath Fan (200 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-l200el/
description: "ENERGY STAR specs for Broan L200EL: 200 CFM, 4.0 CFM/W, 8 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Broan L200EL Exhaust Fan Specifications

ENERGY STAR PD #2405559 · In-line (single-port) · Qualified 2022-12-09

Verified Specification Summary

Tested under HVI protocols, the Broan L200EL exhaust unit achieves 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, covering standard baths up to 200 sq ft on a 8 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L200EL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 200 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 50.0 W (18.2 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan L200EL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan L200EL (EPA filing PD #2405559) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, L200EL (series: LIGHT COMMERCIAL) carries PD #2405559 dating to 2022-12-09. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Zephyr ZSI-E30BS-ES (200.0 CFM) and Zephyr ZSI-E36BS-ES (200.0 CFM).

## What attic duct routing preserves Broan L200EL CFM output?

Short straight 8 in. diameter duct paths retain up to ~82% of open-air capacity on Broan L200EL, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan L200EL measure up on airflow and noise ratings?

Each row below breaks down Broan L200EL certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | L200EL / LIGHT COMMERCIAL | PD ID 2405559 (Qualified 2022-12-09) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (200 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan L200EL CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan L200EL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 200 sq ft | 1 CFM/sq ft @ 200 CFM |
| Tall Bath (9-ft Ceiling) | Up to 177 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 150 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 18.2 kWh/yr (~$2.91/yr) | 50.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 438.0 kWh/yr (~$70.08/yr) | 50.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan L200EL?

Compare Broan L200EL side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Zephyr ZSI-E30BS-ES**](https://siematic-charleston.com/ventilation-fans/zephyr-zsi-e30bs-es/) | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |
| [**Zephyr ZSI-E36BS-ES**](https://siematic-charleston.com/ventilation-fans/zephyr-zsi-e36bs-es/) | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |

## Can you size Broan L200EL for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan L200EL verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan L200EL in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan L200EL for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 200 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 200 sq ft
- **Primary match:** Paired with rigid galvanized 8 in. diameter transition

## How do federal and code standards apply to Broan L200EL?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan L200EL.

### When is Broan L200EL undersized or poorly matched for a bath renovation?

Skip Broan L200EL if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Broan L200EL CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan L200EL registers unlisted 0.25 in. w.g. backpressure figures, making rigid 8 in. diameter duct runs vital.

### How does Broan L200EL sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan L200EL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan L200EL?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan L200EL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L200EL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan L200EL?

Broan L200EL features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan L200EL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L200EL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan L200EL satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan L200EL clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## What neighboring pages and tools support Broan L200EL?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan L200EL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SMT150-200 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt150-200/)
- [Delta SMT150-200LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt150-200led/)
- [Broan L150E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l150e/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)